My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
Reso PC18-01 0008 PC Reso Approving PC & PD at 1175 Marshall Street
RedwoodCity
>
City Clerk
>
Resolutions
>
Planning Commission
>
2018
>
Reso PC18-01 0008 PC Reso Approving PC & PD at 1175 Marshall Street
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/30/2018 9:03:10 AM
Creation date
2/23/2018 8:41:21 AM
Metadata
Fields
Template:
CC Index
CC Index - Document Type
Resolution
Meeting Type
Regular
Agency Type
Planning Commission
Date
2/6/2018
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
shall be installed. Verify any Blue Box phone communication requirements with the <br />Redwood City Police Department. [COA] [POLICE] <br />48. High -Rise Construction - The building is considered a High -Rise and must comply with <br />all codes for High -Rise construction if the height of the top occupied floor slab exceeds 75 <br />feet. Height is measured from the lowest point of the gutter at the lowest street elevation. <br />[SDR][BUILDING] <br />49. Addressing and Access -The following requirements apply: [COA] [FIRE] <br />a. Addresses must be logical, sequential numbers, i.e. First Floor 101, 102, 103, Second <br />Floor 202, 203, 204, as opposed to F303, G401, etc. <br />b. Floor plan maps shall be submitted with unit numbers at all entrances, excluding fire <br />exits. <br />C. Provide a key pad with 24 hour access code for public safety personnel at the main <br />entrance, as opposed to just RFID readers or similar devices <br />50. Elevator Requirements - The following requirements for elevators apply: <br />[SDR] [BUILDING] <br />a. One elevator shall be available for use as an accessible means of egress in case of <br />emergency. <br />b. One elevator shall be connected to backup generator power in order to remain <br />operable during emergencies. This elevator shall be provided with appropriate <br />signage and shall extend to all floors including the lower levels of the parking <br />structure <br />C. All additional elevators shall be connected to battery backup with sufficient power to <br />bring the elevator to the exit level in the event of an emergency. <br />d. All elevators shall be equipped with smoke curtains. <br />Construction -Related Activities <br />51. Verification for Dimensions - All dimensions, including building location on the site, <br />setbacks, building height, etc. shall be verified by a licensed surveyor. A survey report shall <br />be provided to the Building Inspector for review and approval. [COA] [BUILDING] <br />52. Sales and Use Taxes - Applicant shall use good faith efforts to register with the Board of <br />Equalization to create an ID prior to project construction and operation. This maximizes <br />the City's allocation of sales and use taxes associated with project construction. Contact <br />Nancy Murguia, Finance Department, at (650) 780-7097 or <br />nmureuiaC@redwoodcitv.org. [COA][FINANCE] <br />53. Hours of Construction - On -Site Construction activity is permitted between 7:00 a.m. and <br />8:00 p.m. Monday through Friday, except as permitted on weekends by the Building <br />Official, and shall adhere to the City's Noise Ordinance. If possible, the noisiest construction <br />ATN/RESO.0008/PC RESO APPROVING PC & PD AT 1175 MARSHALL STREET <br />REV: 02-07-18 PR <br />Page 13 of 16 <br />
The URL can be used to link to this page
Your browser does not support the video tag.