Laserfiche WebLink
65. Available Water Supply to Project Site - Provide current fire flow information from the <br />water purveyor to indicate the maximum available water flow in gallons per minute (GPM) <br />at a minimum of 20 pounds per square inch (psi) residual pressure. This information must <br />be dated and indicate the information is the most current information available from the water <br />purveyor. [COA] [FIRE] <br />66. Fire Hydrants - The number and location of fire hydrants based on the required fire flow <br />for this project shall be determined utilizing Appendix B and C of the CFC. [COA][FIRE] <br />67. Automatic Fire Sprinkler/Standpipe System Required - As the proposed building is four <br />or more stories in height, the building and garage areas are required to be equipped with <br />standpipe/fire sprinkler systems meeting NFPA Standard 13. Provide plans and hydraulic <br />calculations for the design of these systems. The plans shall also indicate on-site exterior <br />standpipe connections and interior standpipe connections in all of the building's stairwells <br />that need to be included in the hydraulic calculations. [COA][FIRE] <br />68. Fire Department Connections - FDC's to the fire sprinkler/standpipe systems shall be <br />located at the fire access side of all buildings within 50 feet of a fire hydrant. [COA] [FIRE] <br />69. Fire Alarm Systems Required - UL Central Station fully addressable fire alarm systems <br />are required in all buildings meeting NFPA 72. Provide plans and voltage drop calculations <br />for the design of these systems. <br />70. Fire Pits -No fire pits maybe located on the rooftop patios. [COA][FIRE] <br />71. Portable Fire Extinguishers Required - Portable fire extinguishers, with a minimum <br />classification of 2A: l OBC are required to be permanently installed in all buildings within 50 <br />feet of travel from all portions of the building in compliance with NFPA 10 and CFC 906. <br />[COA] [FIRE] <br />72. Addressing and Access - The following requirements apply: [COA] [FIRE] <br />a. Addresses must be logical, sequential numbers, i.e. First Floor 101, 102, 103, <br />Second Floor 202, 203, 204, as opposed to F303, G401, etc. <br />b. Plans shall indicate where on the building exterior the address will be located and <br />the size (minimum 12") in a contrasting background facing the street from which <br />the building takes the address CFC 505. <br />C. Provide a key pad with 24 hour access code for public safety personnel at the main <br />entrance, as opposed to just RFID readers or similar devices <br />73. Elevator Requirements - The following requirements for elevators apply: <br />[SDR] [BUILDING] <br />a. One elevator shall be available for use as an accessible means of egress in <br />case of emergency. <br />ATTY/RESO.0019/PC RESO RECOMMENDING APPROVAL OF GENERAL PLAN — 851 MAIN STREET <br />REV: 03-15-18 PR <br />Page 13 of 16 <br />