My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
Res18 15665
RedwoodCity
>
City Clerk
>
Resolutions
>
City Council
>
2010-2019
>
2018
>
Res18 15665
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/24/2018 8:11:51 AM
Creation date
5/24/2018 8:11:09 AM
Metadata
Fields
Template:
CC Index
CC Index - Document Type
Resolution
Meeting Type
Joint
Agency Type
City Council and Successor Agency and Public Financing Authority
Date
5/21/2018
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
proposed to be used on the North and South fire access lanes. <br />Removable bollards are not approved to be used on fire access lanes. <br />d. Fire apparatus access roads shall be designed and maintained to <br />support the imposed loads of fire apparatus and shall be surfaced so <br />as to provide all weather driving capabilities 503.2.3. Grasspave or DG <br />does not meet this requirement. <br />e. At least one of the required access routes meeting this condition shall be <br />located within a minimum of 15 feet and a maximum of 30 feet from the <br />building, and shall be positioned parallel to one entire side of the building <br />as per 2016 CFC 0105.3. <br />f. Dead-end fire apparatus access roads in excess of 150 feet in length <br />shall be provided with an approved area for turning around fire <br />apparatus at the end 503.2.5. <br />65. Radio Coverage for Emergency Responders — All building and parking <br />garages shall have approved radio coverage for emergency responders within <br />the building. Upon completion of the building construction, a radio coverage test <br />shall be conducted per the applicable codes and standards and if the test fails an <br />Emergency Responders Radio Coverage System shall be installed. Verify any <br />Blue Box phone communication requirements with the Redwood City Police <br />Department. [COA][POLICE] <br />66. High -Rise Construction — Measure the height from the lowest point in the gutter <br />from any and all adjacent streets to the highest occupied finish floor level. Any <br />building measuring 75' or great is a high rise and shall provide all of the code <br />required elements for a high rise. [SDR][BUILDING] <br />67. Addressing and Access — The following requirements apply: [COA][FIRE] <br />a. Addresses must be logical, sequential numbers, i.e. First Floor 101, <br />102, 103, Second Floor 202, 203, 204, as opposed to F303, G401, etc. <br />b. Floor plan maps shall be submitted with unit numbers at all entrances, <br />excluding fire exits. <br />C. Provide a key pad with 24 hour access code for public safety personnel <br />at the main entrance, as opposed to just RFID readers or similar devices <br />68. Elevator Requirements — The following requirements for elevators apply: <br />[SDR][BUILDING] <br />a. One elevator shall be available for use as an accessible means of <br />egress in case of emergency. <br />b. One elevator shall be connected to backup generator power in order to <br />remain operable during emergencies. This elevator shall be provided <br />with appropriate signage and shall extend to all floors including the lower <br />levels of the parking structure <br />C. All additional elevators shall be connected to battery backup with <br />ATTY/RESO.0041/CC RESO DENYING THE APPEAL FOR 353 MAIN STREET RESO NO. 15665 <br />REV: 05-14-18 PR MUFF NO. 603 <br />Page 20 of 29 <br />
The URL can be used to link to this page
Your browser does not support the video tag.