My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
Res18 15665
RedwoodCity
>
City Clerk
>
Resolutions
>
City Council
>
2010-2019
>
2018
>
Res18 15665
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/24/2018 8:11:51 AM
Creation date
5/24/2018 8:11:09 AM
Metadata
Fields
Template:
CC Index
CC Index - Document Type
Resolution
Meeting Type
Joint
Agency Type
City Council and Successor Agency and Public Financing Authority
Date
5/21/2018
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
(psi) residual pressure. This information must be dated and indicate the <br />information is the most current information available from the water purveyor. If <br />the available water supply does not meet fire code requirements, water system <br />infrastructure improvements will be required. <br />58. Fire Hydrants - The number and location of Fire Hydrants based on the <br />required fire flow for this project shall be determined utilizing Appendix B <br />and C of the CFC. <br />59. Automatic Fire Sprinklers / Standpipe Systems - The proposed building <br />is required to be equipped with an automatic fire sprinkler system and a <br />standpipe system with connections in stairwells and the roof meeting NFPA <br />Standard 13. Provide plans and hydraulic calculations for the design of the <br />systems. <br />60. Fire Department Connect ions -FDC's to the fire sprinkler / stand pipe <br />systems shall be located at the fire access side of the buildings within 50 <br />feet of a Fire Hydrant. <br />61. Fire Alarm System Required -UL Central Station fully add ressable fire <br />alarm system is required meeting NFPA 72. Provide plan s and voltage drop <br />calculations for the design of these systems. <br />62. Premises Identification (Address Numbers) - Indicate on the plans where <br />the premises identification (address) will be located and the size (minimum 1 <br />2") in a contrasting background facing the street from which the building takes <br />the address CFC 505. <br />63. Portable Fire Extinguishers Required - Portable fire extinguishers, with a <br />minimum classification of 2A: I OBC are required to be permanently installed <br />in all buildings in the common areas within 50 feet of travel from all <br />portions of the building in compliance with NFPA 10 and CFC 906. <br />64. Fire Apparatus Access: <br />a. As the proposed structure exceeds 30 feet in height, at least two <br />means of fire apparatus access shall be provided CFC D 104.1. <br />b. As the proposed structure exceeds 62,000 square feet in area, two <br />separate and approved fire apparatus access roads are required CFC D <br />104.2. <br />C. The width of the required fire apparatus access roads shall be a <br />minimum of 26 feet to accommodate aerial apparatus D 105.2. And have <br />an unobstructed vertical clearance of not less than 13 feet 6 inches <br />503.2.1. The plans indicate trees and landscaping encroaching on the <br />fire access lane. The plans also indicate that removable bollards are <br />ATTY/RESO.0041/CC RESO DENYING THE APPEAL FOR 353 MAIN STREET RESO NO. 15665 <br />REV: 05-14-18 PR MUFF NO. 603 <br />Page 19 of 29 <br />
The URL can be used to link to this page
Your browser does not support the video tag.