<br />Page 3 <br /> <br />Green Environment inc. <br />Subsurface Investigation Proposal <br />City Parking Lot Between 2053 and 2065 Broadway Avenue, Redwood City, CA <br /> <br />. <br /> <br />Measure depth-to-water in the temporary well casings using an electronic water level <br />sounder, express measurements relative to a fixed, labeled point on the top surface. <br /> <br />. <br /> <br />Following groundwater sampling, remove the well casings and tremie grout the <br />boreholes with neat cement upward from the bottom of each boring and manage <br />displaced groundwater as a waste. <br /> <br />Task 5. Groundwater Monitoring Well Installation <br /> <br />. <br /> <br />Construct a shallow groundwater monitoring well (Well GEI-MWI) at the BAGG <br />Boring EB-3 location. The well will be constructed of four (4)-inch polyvinyl chloride <br />(PVC) casing set at a maximum twelve (12) feet depth. The well will be gently <br />surged prior to emp1acing a bentonite seal in order to settle the filter pack. The top of <br />the well casing will have a locking well cap and a traffic-rated well box. <br /> <br />. After well construction, the well will be developed by a C57 licensed driller to <br />prepare the well for groundwater sampling. <br /> <br />. <br /> <br />Collect and dispose of well purge water offsite. <br /> <br />. <br /> <br />Survey the elevation and location of the new groundwater monitoring well as well as <br />the five (5) GEl borings and past BAGG borings relative to a local City bench mark. <br /> <br />Task 6. Well Groundwater Sampling <br /> <br />. <br /> <br />Gauge and collect a groundwater sample from Well GEl-MWI using standard <br />industry protocol on a quarterly basis for one (1) year, a total of four (4) sampling <br />events. <br /> <br />. Place water generated from the well purge and decon activities in a DOT 55-gallon <br />drum. Seal, label and place the drum in the City parking lot for temporary storage <br />prior to appropriate offsite disposal (paid by GEl, City identified as Generator). <br /> <br />Task 7. Laboratory Analyses <br /> <br />. <br /> <br />Submit the soil and groundwater samples to a California-certified laboratory <br />following chain of custody protocol. <br /> <br />. <br /> <br />Analyze a maximum of sixteen (16) soil samples for total extractable petroleum <br />hydrocarbons (TEPH) via Environmental Protection Agency (EPA) Method 8015M <br />