RES 0 L UTI 0 N ~ Q. 9 222 StP 1 3 1982 RESOLUTION FINDING AND DETERMINING THAT, BECAUSE OF LOCAL CONDITIONS, THE PUBLIC HEALTH, SAFETY, WELFARE AND NECESSITY, REQUIRE CHANGES OR MODIFICATIONS TO CERTAIN PROVISIONS OF THE UNIFORM FIRE CODE 1982 EDITION, AS PUBLISHED BY THE INTERNATIONAL CONFERENCE OF BUILDING OFFICIALS AND THE WESTERN FIRE CHIEFS ASSOCIATION, AND AS ADOPTED BY REFERENCE, AND MADE APPLICABLE TO THE CITY OF REDWOOD CITY
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
<br />(f)fhe travel time to a fire within the City is <br />impeded by the following conditions, unique <br />to Redwood City: <br /> <br />(1) Railroad tracks divide the City into three <br />(3) sections, and response requiring crossing <br />of these tracks faces potential delay for <br />emergency vehicles. The heavily populated <br />northern postion of the City is without an <br />overcrossing; <br /> <br />(2) There is an absence of parallel emergency <br />response routes to Highway 101 or El Camino <br />Real and an absence of adequate north/south <br />emergency response routes west of the railroad <br />tracks, impeding access to a heavily populated <br />section of the City; <br /> <br />(3) A growing community of single family and multi- <br />family dwellings presently exists on the <br />easterly side of Highway 101, which is itself <br />a potential physical barrier to response to <br />a fire. <br /> <br />(g) that, on the basis of an analysis per:ormed by <br />Mr. Warren Kimball, a noted Fire Service Specialist, <br />two (2) to four (4) gallons of water per minute <br />are required to be applied to extinguish fire in <br />each 100 cubic feet of a building involved in a <br />fire. On that basis, it would require at least <br />2,250 gallons per minute be applied for extinguish- <br />ment of a fire totally involving a 7,500 square foot <br />building. Accepted Fire Department good practice <br />would require additional"manpower and waterflow if <br />area separation walls, used to circumvent the 7500 <br />square foot requirement, were present. The City <br />Fire Department, with multiple alarm response <br />involving on-duty personnel and present equipment <br />is capable of supplying approximately 1,000 gallons <br />of water per minute. <br /> <br />(h) Since an automatic monitored sprinkler system is <br />designed to suppr8ss or contain fire, and to <br />automatically alert the Fire Department of the <br />r:;enacing presence of a fire the existence of such <br />a system will increase the likelihood that a building <br />on fire will not be totally involved with fire by <br />the time the Fire Department responds, and that the <br />fire will be controlled to a level consistent with <br />fire fighting resources provided by the City of <br />Redwood City. <br /> <br />(i) The requirements of the aforesaid local amendment <br />fulfill the City's desire to minimize its fire <br />fighting and fire prevention costs since the City <br />cannot afford to pay for increased levels of fire <br />fighting which would be the result of the application <br />of normal uniform fire code and building code require- <br />ments. <br />