My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
Ord 2428
RedwoodCity
>
City Clerk
>
Resolutions
>
City Council
>
Working
>
Ordinances
>
2010-2019
>
Ord 2428
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/11/2019 2:49:59 PM
Creation date
10/11/2019 2:49:56 PM
Metadata
Fields
Template:
CC Index
CC Index - Document Type
Ordinance
Meeting Type
Joint
Agency Type
City Council and Successor Agency and Public Financing Authority
Date
1/9/2017
Description
AN ORDINANCE OF THE CITY OF REDWOOD CITY REPEALING ARTICLES IV, V, VI, VII, VIII, IX AND X OF CHAPTER 9 OF THE REDWOOD CITY MUNICIPAL CODE AND ADOPTING NEW ARTICLES IV, V, VI, VII, VIII, IX AND X OF CHAPTER 9 OF THE REDWOOD CITY MUNICIPAL CODE ADOPTING TITLE 24, PARTS 2 (VOLUMES 1 AND 2), 2.5, 3, 4, 5, 6, 8, 10 AND 11 OF THE CALIFORNIA CODE OF REGULATIONS, NAMELY THE 2016 CALIFORNIA BUILDING, RESIDENTIAL, ELECTRICAL, MECHANICAL, PLUMBING, ENERGY, HISTORICAL BUILDING, EXISTING BUILDING, AND GREEN BUILDING STANDARDS CODES, TOGETHER WITH CERTAIN AMENDMENTS, EXCEPTIONS, MODIFICATIONS AND ADDITIONS, THERETO, AND THE 2015 INTERNATIONAL EXISTING BUILDING, PROPERTY MAINTENANCE, UNIFORM PLUMBING, AND UNIFORM MECHANICAL CODES
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
01109/2017 <br />slab. The Planning Division shall approve all materials and designs for driveways. <br />Under habitable rooms of Groups R occupancies, a vapor barrier approved by the <br />Building Official shall be installed beneath the concrete slab floor. Single -ply plastic <br />vapor barriers shall not be used. An approved base material of suitable <br />consistency, compaction, and thickness shall be provided directly under the <br />concrete slab vapor barrier to retard capillary action. Two (2) inches of sand shall <br />be provided between the vapor barrier and the concrete slab. The top of the <br />concrete floor slab shall be a minimum six (6) inches above exterior finished grade. <br />Sec. 9.65. SECTION R506.1 OF THE RESIDENTIAL CODE AMENDED: Section R506 of <br />the Residential Code is amended to add a new Section R506.1.1 to read as follows: <br />R506.1.1 Concrete slab floors. Concrete slab floors, garage slabs, and driveways <br />shall have a minimum thickness of three and one-half (3 1/2) inches and shall be <br />reinforced with a minimum six (6) inch by six (6) inch by six (6) gauge welded wire <br />fabric or equivalent area of reinforcing. Welded wire fabric manufactured in mats <br />shall be used. All reinforcement shall be appropriately supported in order to keep <br />the reinforcement in the mid -depth of the slab until the completion of the concrete <br />pour. <br />Under habitable rooms of Groups R occupancies, a vapor barrier approved by the <br />Building Official shall be installed beneath the concrete slab floor. Single -ply <br />plastic vapor barriers shall not be used. An approved base material of suitable <br />consistency, compaction, and thickness shall be provided directly under the <br />concrete slab vapor barrier to retard capillary action. Two (2) inches of sand shall <br />be provided between the vapor barrier and the concrete slab. The top of the <br />concrete floor slab shall be a minimum six (6) inches above exterior finished grade. <br />Sec. 9.66. TABLE 2308.5.11, GYPSUM SHEATHING IN THE TABLE OF THE <br />BUILDING CODE AMENDED: Table 2308.5.11, Line 5 is amended to read as follows: <br />Gypsum sheathing shall not be considered for a braced wall panel. <br />Sec. 9.67. SECTION R602.10.4 OF THE RESIDENTIAL CODE AMENDED: Section <br />R602.10.4 is amended to add a new section R602.10.4.4 to read as follows: <br />R602.10.4.4. Limits on methods GB and PCP. In Seismic Design Categories D0, <br />D1, and D2, Method GB is not permitted for use as intermittent braced wall panels, <br />but gypsum board is permitted to be installed when required by this Section to be <br />placed on the opposite side of the studs from other types of braced wall panel <br />sheathing. In Seismic Design Categories D0, D1, and D2, the use of Method PCP <br />is limited to one-story single family dwellings and accessory structures. <br />Sec. 9.68. ADOPTION OF APPENDICES F, I, AND J. Appendices F, I, and J as set <br />ATTY/ORD.433/BUILDING CODE ADOPTION <br />REV: 12-19-16 RL <br />Page 8 of 16 <br />ORDINANCE NO. 2428 <br />MUFF NO. 305 <br />
The URL can be used to link to this page
Your browser does not support the video tag.