Laserfiche WebLink
<br /> .-- <br /> FXS:dft f '18/93 (017/11) <br /> "Section 9.49. Table No. 32-A of the Building <br /> Code is hereby amended to read as follows: <br /> TABLE NO. 32-A MINIMUM ROOF CLASSES <br /> TYPES OF CONSTRUcnON <br /> OCCUPANCY I n m IV v <br /> F.R. F.R. 1-BR N 1-BR N H.T. 1-HR N <br /> 1.-1 II II - - - - - - - <br /> A 2-2.1 II II II - II - II II - <br /> 1.-3 II II II II II II II II II <br /> 1.-4 II II II II II II II II II <br /> II 1-2 II II II II II II II II II <br /> II 3-4 B II II II II II II B II <br /> E II II II II II II II II II <br /> H-1 A A A A - - - - - <br /> H-2 TIUlU 7 A II II II II II II II II <br /> 1-1.1-1.2-2 A II B - II - II II - <br /> I-3 A II II - II - - II - <br /> K II II II II II II II II II <br /> R-1 II II II II II II II II II <br /> R-3 II II II II II II II II II <br /> A-CLASS "Z.' ROOFJ:JIG 8-CLASS "8- ROOFJ:HG <br /> "Section 9.50. Table No. 32-B-2 Item No. 1 Deck <br /> Requirement of the Building Code is hereby amended to <br /> read as follows: <br /> TABLE NO.32-B2--WOOD SHXNGLE OR SHAKE APPLXCATXON <br /> WOOD SHINGLES WOOD SHAKES <br /> ROOF SLOPE NOT PERMITTED BELOW NOT PERMITTED BELOW <br /> 3 :12 4:12 (l) <br /> SEE TABLE NO. 32-C SEE TABLE NO. 32-C <br /> SHINGLES AND SHAKES SHALL BE APPLIED TO ROOFS <br /> WITH SOLID SHEATHING. <br /> 1. DECK <br /> REQUIREMENT SHEATHING SHALL BE MINIMUM 1/2" NOMINAL <br /> THICKNESS AND CONFORM TO SECTIONS 2516 (i) AND <br /> 2517 (h) 8 OF THE BUILDING CODE. <br /> 3 <br /> -. <br />