8.113. - Page 40 of 63 <br />EXCEPTION to 150.1(c) 15.A.5 Electrically -Heated Mixed -Fuel buildings do <br />not need to include battery or solar water heating. <br />B. Mixed -Fuel Multifamily <br />1. Slab floor perimeter insulation shall be installed with an R -value of equal to <br />or greater than R10. The minimum depth of concrete -slab floor perimeter <br />insulation shall be 16 inches or the depth of the footing of the building, <br />whichever is less. <br />2. Design the hot water distribution system to meet minimum requirements for <br />the basic compact hot water distribution credit according to the procedures <br />outlined in the 2019 Reference Appendices RA4.4.6 <br />3. Central Fan Integrated Ventilation Systems. Central forced air system fans <br />used to provide outside air, shall have an air -handling unit fan efficacy less <br />than or equal to 0.35 W/CFM. The airflow rate and fan efficacy requirements <br />in this section shall be confirmed through field verification and diagnostic <br />testing in accordance with all applicable procedures specified in Reference <br />Residential Appendix RA3.3. Central Fan Integrated Ventilation Systems <br />shall be certified to the Energy Commission as Intermittent Ventilation <br />Systems as specified in Reference Residential Appendix RA3.7.4.2. <br />4. Include either: <br />a. 2.75 kWh of battery storage per dwelling unit, or <br />b. A solar water heating system with a minimum solar savings <br />fraction of 0.20. <br />EXCEPTION to 150.1(c) 15.8.4 Electrically Heated Mixed -Fuel Buildings do <br />not need to include battery or solar water heating. <br />Sec. 9.233. - SECTION 202 OF THE GREEN BUILDING STANDARDS CODE <br />AMENDED: <br />SECTION 202 of the Green Building Standards Code is amended to add definitions for <br />"EV Capable", "Level 1 EV Ready Circuit", "Level 2 EV Ready Circuit", and "Electric <br />Vehicle Charging Station (EVCS)" to read as follows: <br />EV CAPABLE: A parking space linked to a listed electrical panel with sufficient <br />capacity to provide at least 110/120 volts and 20 amperes to the parking space. <br />Raceways linking the electrical panel and parking space only need to be installed <br />in spaces that will be inaccessible in the future, either trenched underground or <br />where penetrations to walls, floors, or other partitions would otherwise be required <br />for future installation of branch circuits. Raceways must be at least 1" in diameter <br />and may be sized for multiple circuits as allowed by the California Electrical Code. <br />The panel circuit directory shall identify the overcurrent protective device space(s) <br />reserved for EV charging as "EV CAPABLE." Construction documents shall <br />indicate future completion of raceway from the panel to the parking space, via the <br />installed inaccessible raceways. <br />LEVEL 1 EV READY CIRCUIT: A parking space served by a complete electric <br />circuit with a minimum of 110/120 volt, 20 -ampere capacity including electrical <br />ATTY/ORD.504/CC ORDINANCE ADDING CALIFORNIA ENERGY CODE & GREEN BUILDING STANDARDS <br />REV: 10-24-19 RL <br />Page 12 of 18 <br />184 <br />