My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
AgdaPkt 2007-12-17
RedwoodCity
>
City Clerk
>
Agenda Packets
>
2000-2009 partial
>
2007
>
AgdaPkt 2007-12-17
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/24/2013 12:50:48 PM
Creation date
12/13/2007 4:29:15 PM
Metadata
Fields
Template:
CC Index
CC Index - Document Type
Agenda Packet
Meeting Type
Joint
Agency Type
City Council and Redevelopment Agency
Date
12/17/2007
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
671
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
7A <br /> Page 5 <br /> Section 108.2 Schedule of Fees. The Buiiding Off'rcial shall charge a fee to the <br /> person �ling an application or requesting services for such permit, such fee to be <br /> established by resolution of the Council. <br /> (Ord. N�. 2241, § 2, 12-5-2002) <br /> Sec. 9.43. TABlE. '1505.'t �F THE BUILDING CODE AMENDED: <br /> Tabfe 1505.1 of the Building Code is hereby amended to read as follows: <br /> TABLE 1505.1 <br /> M(NIMUM ROOF COVERING CLASSIFICATI4N <br /> FGr TYPES OF CONSTRUCTION <br /> !A IB IIA !IB IIIA IIIB iV VA VB <br /> B B B B B B B B B <br /> {�rd. No. 2241, § 2, 12-5-02) . <br /> Secs. 9.44 - 9.72. RESERVED. <br /> Sec. 9.73. SECTION 1914 OF THE BUILDING CO[3E AMENDED: Section <br /> 1910 of the Building Code is hereby amended ta read as follows: <br /> Sectian 1910.1. Concrete Slabs on Grade. This section shall apply to concrete <br /> slabs on grade in consfruction related to Groups R and U occupancies only. <br /> Section 1910.1.1. Concrete slab floors, garage slabs, and driveways shall have a <br /> minimum thickness of three and one-half (3 1/2} inches and shall be reinforced <br /> with a minimum six (6) inch by six (6) inch by six {6) gauge welded wire fabric or <br /> equivalent area of reinforcing. Welded wire fabric manufactured in mats shal! be <br /> used. All reinforcement shali be appropriately supported in order to Keep the <br /> reinfarcement in the mid-depth of the slab until the completion of the concrete <br /> p�ur. <br /> Section 1910.2. Under habitable rooms of Groups R occupancies, a vapor barrier <br /> approved by the Building Officia! shall be ir�stalled be►�eat� the concrete slab <br /> floor. Single-ply plas#ic vapor barriers shall no# be used. An approved base <br /> rnaterial of suitable consistency, compaction, and thickness shail be provided <br /> directly under the concrete slab vapor barrier to retard capillary action. Two (2) <br /> inches of sand shall be provided between the vapor barrier and the concrete <br /> slab. T�e top af the concrete floor slab shall be a minimum six {6) inches above <br /> exterior finisl�ed grade. <br /> (Ord. No. 2241, § 2, 12-5-2002) <br /> Secs. 9.74 -9.82. RESERVED. <br /> Atty/Ord/0rd.291 <br /> 120307 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.