My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
Ord08 2324
RedwoodCity
>
City Clerk
>
Ordinances
>
2000-2009
>
2008
>
Ord08 2324
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/14/2016 12:21:16 PM
Creation date
1/17/2008 4:56:31 PM
Metadata
Fields
Template:
CC Index
CC Index - Document Type
Ordinance
Meeting Type
Regular
Agency Type
City Council
Date
1/14/2008
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
01/14/2008 <br /> Section 108.2 Schedule of Fees. The Building Official shall charge a fee to the <br /> person filing an application or requesting services for such permit, such fee to be <br /> established by resolution of the Council. <br /> (Ord. No. 2241, § 2, 12-5-2002) <br /> Sec. 9.43. TABLE. 1505.1 OF THE BUILDING CODE AMENDED: <br /> Table 1505.1 of the Building Code is hereby amended to read as follows: <br /> TABLE 1505.1 <br /> MINIMUM ROOF COVERING CLASSIFICATION <br /> FOR TYPES OF CONSTRUCTION <br /> IA IB IIA IIB IIIA IIIB IV VA VB <br /> B B B B B B B B B <br /> (Ord. No. 2241, § 2, 12-5-02) <br /> Secs. 9.44 - 9.72. RESERVED. <br /> Sec. 9.73. SECTION 1910 OF THE BUILDING CODE AMENDED: Section <br /> 1910 of the Building Code is hereby amended to read as follows: <br /> Section 1910.1. Concrete Slabs on Grade. This section shall apply to concrete <br /> slabs on grade in construction related to Groups R and U occupancies only. <br /> Section 1910.1.1. Concrete slab floors, garage slabs, and driveways shall have a <br /> minimum thickness of three and one-half (3 1/2) inches and shall be reinforced <br /> with a minimum six (6) inch by six (6) inch by six (6) gauge welded wire fabric or <br /> equivalent area of reinforcing. Welded wire fabric manufactured in mats shall be <br /> used. All reinforcement shall be appropriately supported in order to keep the <br /> reinforcement in the mid-depth of the slab until the completion of the concrete <br /> pour. <br /> Section 1910.2. Under habitable rooms of Groups R occupancies, a vapor barrier <br /> approved by the Building Official shall be installed beneath the concrete slab <br /> floor. Single-ply plastic vapor barriers shall not be used. An approved base <br /> material of suitable consistency, compaction, and thickness shall be provided <br /> directly under the concrete slab vapor barrier to retard capillary action. Two (2) <br /> inches of sand shall be provided between the vapor barrier and the concrete <br /> slab. The top of the concrete floor slab shall be a minimum six (6) inches above <br /> exterior finished grade. <br /> (Ord. No. 2241, § 2, 12-5-2002) <br /> Secs. 9.74 - 9.82. RESERVED. <br /> Atty/Ord/Ord.291 2324 <br /> 120307 3 FORMERLY MUFF#305 <br />
The URL can be used to link to this page
Your browser does not support the video tag.