My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
Ord08 2324
RedwoodCity
>
City Clerk
>
Ordinances
>
2000-2009
>
2008
>
Ord08 2324
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/14/2016 12:21:16 PM
Creation date
1/17/2008 4:56:31 PM
Metadata
Fields
Template:
CC Index
CC Index - Document Type
Ordinance
Meeting Type
Regular
Agency Type
City Council
Date
1/14/2008
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
01/14/2008 <br /> Sec. 9.83. SECTION 2308.9.3, ITEMS 5 AND 7 OF THE BUILDING CODE <br /> AMENDED: Section 2308.9.3, Items 5 and 7 of the Building Code are hereby amended <br /> to read as follows: <br /> Section 2308.9.3. Conventional Light-Frame Construction Provisions (Bracing) <br /> are amended as follows. <br /> Item 5: Delete Section 2308.9.3, Item 5 which allows the use of gypsum board <br /> for bracing. <br /> Item 7: Portland cement plaster on studs spaced 16 inches (406mm) on center <br /> installed in accordance with Section 2510. Limited to one-story structures of R <br /> and U occupancies. <br /> (Ord. No. 2241, § 2, 12-5-2002) <br /> Sec. 9.84. SECTION 2603.4.1.5 OF THE BUILDING CODE AMENDED: <br /> Section 2603.4.1.5 of the Building Code is hereby amended to read as follows: <br /> Section 2603.4.1.5 Foam plastic insulation under a roof assembly or roof <br /> covering that is installed in accordance with the code and the manufacturer's <br /> instructions shall be separated from the interior of the building by wood structural <br /> panel sheathing not less than 0.47 inch (11.9 mm) in thickness bonded with <br /> exterior glue, with edges supported by blocking, tongue-and-groove joints or <br /> other approved type of edge support, or an equivalent material. A thermal barrier <br /> is not required for foam plastic insulation that is a part of a Class A or B roof- <br /> covering assembly, provided the assembly with the foam plastic insulation <br /> satisfactorily passes FM 4450 or UL 1256. <br /> (Ord. No. 2241, § 2, 12-5-2002) <br /> Sec. 9.85. SECTION J102.1, APPENDIX J OF THE BUILDING CODE <br /> AMENDED: Section J102.1, Appendix J of the Building Code is hereby amended to <br /> add the definition of Engineered Grading: <br /> Section J102.1. Definitions. For the purpose of this appendix chapter, the <br /> terms, phrases and words listed in this section and their derivatives shall have the <br /> indicated meanings. <br /> BENCH. A relatively level step excavated into earth material on which fill is to be <br /> placed. <br /> COMPACTION. The densification of a fill by mechanical means. <br /> CUT. See excavation <br /> DOWN DRAIN. A device for collecting water from a swale or ditch located on or <br /> above a slope, and safely delivering it to an approved drainage facility. <br /> Atty/Ord/Ord.291 2324 <br /> 120307 4 FORMERLY MUFF#305 <br />