7.A. - Page 194 of 285 2019 Nonresidential New Construction Reach Code Cost Effectiveness Study <br />Figure 11. Medium Retail HVAC System Costs <br />Climate Zone <br />Mixed Fuel <br />Baseline <br />All Electric System <br />Incremental cost <br />for All -Electric <br />CZ01 <br />$328,312 <br />$333,291 <br />$4,978 <br />CZ02 <br />$373,139 <br />$373,702 <br />$563 <br />CZ03 <br />$322,849 <br />$326,764 <br />$3,915 <br />CZ04 <br />$329,900 <br />$335,031 <br />$5,131 <br />CZ05 <br />$359,888 <br />$362,408 <br />$2,520 <br />CZ06 <br />$335,728 <br />$341,992 <br />$6,265 <br />CZ07 <br />$345,544 <br />$349,808 <br />$4,265 <br />CZ08 <br />$368,687 <br />$369,792 <br />$1,104 <br />CZ09 <br />$415,155 <br />$411,069 <br />$(4,087) <br />CZ10 <br />$345,993 <br />$346,748 <br />$755 <br />CZ11 <br />$418,721 <br />$414,546 <br />$(4,175) <br />CZ12 <br />$405,110 <br />$400,632 <br />$(4,477) <br />CZ13 <br />$376,003 <br />$375,872 <br />$(131) <br />CZ14 <br />$405,381 <br />$406,752 <br />$1,371 <br />CZ15 <br />$429,123 <br />$427,606 <br />$(1,517) <br />CZ16 <br />$401,892 <br />$404,147 <br />$2,256 <br />3.3.1.3 Small Hotel <br />The small hotel has two different baseline equipment systems, one for the nonresidential spaces and one <br />for the guest rooms. The nonresidential HVAC system includes two gas hot water boilers, four packaged <br />rooftop units and twelve VAV terminal boxes with hot water reheat coil. The SHW design includes a small <br />electric water heater with storage tank. The residential HVAC design includes one single zone AC unit with <br />gas furnace for each guest room and the water heating design includes one central gas storage water <br />heater with a recirculation pump for all guest rooms. <br />For the small hotel all -electric design, the Reach Code Team assumed the nonresidential HVAC system to <br />be packaged heat pumps with electric resistance VAV terminal units, and the SHW system to remain a <br />small electric resistance water heater. <br />For the guest room all -electric HVAC system, the analysis used a single zone (packaged terminal) heat <br />pump and a central heat pump water heater serving all guest rooms. Central heat pump water heating <br />with recirculation serving guest rooms cannot yet be modeled in CBECC-Com, and energy impacts were <br />modeled by simulating individual heat pump water heaters in each guest room. The reach code team <br />believes this is a conservative assumption, since individual heat pump water heaters will have much <br />higher tank standby losses. The Reach Code Team attained costs for central heat pump water heating <br />installation including storage tanks and controls and used these costs in the study. <br />Cost data for small hotel designs are presented in Figure 12. The all -electric design presents substantial <br />cost savings because there is no hot water plant or piping distribution system serving the nonresidential <br />spaces, as well as the lower cost of packaged terminal heat pumps serving the residential spaces <br />compared to split DX/furnace systems with individual flues. <br />19 © 2019-07-25 <br />446 <br />