77. Gurney Accommodating Elevators Required - Elevators are required to be provided in all buildings <br />that are four stories or more. Elevators shall be provided for fire department emergency access to <br />all floors. The elevator car shall be of such a size and arrangement to accommodate an ambulance <br />stretcher 24 inches by 84 inches with not less than 6 -inch radius corners, in the horizontal, open <br />position and shall be identified by the international symbol for emergency medical service. The <br />symbol shall not be less than 3 inches high and shall be placed inside on both sides of the hoist -way <br />door frame CBC 3002.4. <br />a. The plans indicate that this condition will be addressed. <br />78. Portable Fire Extinguishers Required - Portable fire extinguishers, with a minimum classification of <br />2A:10BC are required to be permanently installed in all buildings within 75 feet of travel from all <br />portions of the building in compliance with NFPA 10 and CFC 906. <br />79. Radio Coverage for Emergency Responders —All building and parking garages shall have approved <br />radio coverage for emergency responders within the building. Upon completion of the building <br />construction, a radio coverage test shall be conducted per the applicable codes and standards and <br />if the test fails an Emergency Responders Radio Coverage System shall be installed. Verify any Blue <br />Box phone communication requirements with the Redwood City Police Department. [COA][POLICE] <br />80. High -Rise Construction —The building is considered a High -Rise and must comply with all codes for <br />High -Rise construction if the height of the top occupied floor slab exceeds 75 feet. Height is <br />measured from the lowest point of the gutter at the lowest street elevation. [SDR][BUILDING] <br />81. Addressing and Access — The following requirements apply: [COA][FIRE] <br />a. Addresses must be logical, sequential numbers, i.e. First Floor 101, 102, 103, Second <br />Floor 202, 203, 204, as opposed to F303, G401, etc. <br />b. Floor plan maps shall be submitted with unit numbers at all entrances, excluding fire <br />exits. <br />c. Provide a key pad with 24 hour access code for public safety personnel at the main <br />entrance, as opposed to just RFID readers or similar devices <br />82. Elevator Requirements — The following requirements for elevators apply: [SDR][BUILDING] <br />a. One elevator shall be available for use as an accessible means of egress in case of <br />emergency. <br />b. One elevator shall be connected to backup generator power in order to remain <br />operable during emergencies. This elevator shall be provided with appropriate <br />signage and shall extend to all floors including the lower levels of the parking <br />structure. <br />c. All additional elevators shall be connected to battery backup with sufficient power to <br />bring the elevator to the exit level in the event of an emergency. <br />d. All elevators shall be equipped with smoke curtains. <br />ATTY/RESO.0125/PC RESO SOUTH MAIN MIXED USE PROJECT— ENTITLEMENT RESO. NO. 15908 <br />REV: 11-03-2020 PR MUFF NO. 601 <br />Page 34 of 38 <br />