My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
Agmt09 South Bay Recycling, LLC
RedwoodCity
>
City Clerk
>
Agreements
>
2000-2009
>
2009
>
Agmt09 South Bay Recycling, LLC
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/1/2009 10:33:57 AM
Creation date
8/31/2009 11:36:32 AM
Metadata
Fields
Template:
Agreement
Contractor Name
South Bay Recycling, LLC
PROJECT NAME
Operation of Shoreway Recycling and Disposal Center
RMP File Number
304
Date
7/30/2009
Reso Ref
14964
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
251
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
<br />Table 1: Samples per Load and Results <br /> <br /> Quarterly samples and Annual samples and results <br /> results <br /> Estimated Number of Approximate N umber of Approximate <br />Material stream sample samples statistical samples statistical <br /> weight error range error range <br />Commercial <br />Source- <br />Separated and 150lbs 12 3% 48 1.5% <br />Targeted <br />Recyclable <br />Materials <br />Commercial <br />Organic 200lbs 12 8% 48 4% to 5% <br />Materials <br />Commercial 150lbs 12 1% 48 0.5% <br />Plant Materials <br />Single-Family ~ <br />Targeted 150 Ibs 12 2% 48 1% <br />Recyclable <br />Materials <br />Single-Family <br />Organic 150lbs 12 1% 48 0.5% <br />Materials <br /> <br />The error ranges shown above shall be interpreted as follows. When the calculation <br />method described below provides the Measured Contamination Level in a material <br />stream, the estimate will be expressed in terms of percent by weight of the entire <br />material stream. The error range around the estimate reflects a percent by weight of the <br />entire material stream. Thus, if the Measured Contamination Level in a given material <br />stream is five percent (50/0), plus or minus one percent (1010), then ninety percent (900/0) <br />confidence that the Contamination Level is between four percent (40/0) and six percent <br />(60/0) of the total material stream is achieved. <br /> <br />It is expected that a two (2) person crew can collect, sort, and weigh approximately <br />twelve (12) samples in an eight (8) to ten (10) hour period, assuming a constant supply- <br />of samples is available. Therefore, two (2) sorters working approximately five (5) days <br />per quarter will collect and sort the desired number of samples to assess all five (5) <br />material streams, assuming there are enough inbound loads during that time period to <br />provide the desired number of samples. <br /> <br />To capture seasonal variations, sampling events will be conducted during each of the <br />four (4) calendar quarters. In addition, sampling events will be scheduled to avoid days <br />during and immediately following major holidays, and will be scheduled within each <br />quarter to match as closely as possible with a single collection cycle for Contractor. <br /> <br />4. Field Procedures <br />The field procedures are described in the following nine (9) steps, and shall be followed <br />by the applicable party (Le., Contractor, Operator, AUTHORITY, or a third party <br />designated by the AUTHORITY). <br /> <br />· Advanced preparation for regularly scheduled testing <br /> <br />Facility Agreement. Attachment 2-H <br />Contamination Measurement Methodology <br />Page 3 of 19 <br />
The URL can be used to link to this page
Your browser does not support the video tag.