My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
Agmt22 E Source Companies, LLC
RedwoodCity
>
City Clerk
>
Agreements
>
2020-2029
>
2022
>
Agmt22 E Source Companies, LLC
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/29/2025 11:24:31 AM
Creation date
8/31/2022 2:19:54 PM
Metadata
Fields
Template:
Agreement
Contractor Name
E Source Companies, LLC
PROJECT NAME
technical assistance to comply with state regulatory requirements related to water loss
RMP File Number
304
Date
8/26/2022
MO Ref
22-138
Amendment
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
REV: 08-05-22 RL <br />except for billing data) <br />Complete the water audit compilation in the AWWA Free Water Audit <br />Software <br />Produce supporting documentation required for level 1 validation <br />Identify strengths and shortcomings of available information and <br />instruments <br />2. b. Billing Data Analysis <br />If requested and approved by the Public Works Director or their designee, <br />Consultant shall intake and review the City’s billing data for the audit period. In <br />this task, Consultant shall: <br />Review data for integrity and completeness <br />Prorate billing data for best alignment with production data <br />Identify and visualize anomalous records <br />Identify notable findings and potential errors <br />2. c. Source Meter Volumetric Accuracy Testing & Reporting <br />If requested and approved by the Public Works Director or their designee, <br />Consultant shall design and conduct a volumetric source meter accuracy test. <br />Source meter accuracy testing establishes a field-verified volume of water <br />supplied, the baseline of the water audit. For each source meter accuracy test, <br />Consultant shall: <br />Conduct a site visit <br />Draft a test design <br />Conduct a volumetric accuracy test with comparative meter or reservoir <br />reference volume <br />Complete a data chain assessment, if relevant <br />Analyze test results <br />Document test procedure for future meter accuracy investigation <br />2. d. Field Pressure Survey & Reporting <br />If requested and approved by the Public Works Director or their designee, <br />Consultant shall identify the best fit goals for pressure data collection for the City. <br />The following table summarizes three potential goals and the approach toward <br />achieving each one. <br />ATTY/AGR.2022.231/E Source Companies, LLC (Water Loss Consultation Services) (Page 12 of 17)
The URL can be used to link to this page
Your browser does not support the video tag.