Laserfiche WebLink
102.27 <br />Duration® <br />Exterior Acrylic Low Lustre <br />K30-Series <br />CHARACTERISTICS <br />Duration® Exterior Latex Coating is the result of advances in acrylic technology. Duration uses PermaLast® technology to provide you with the most durable and longest lasting coating available for protecting the outside of your home. <br />VinylSafe™ paint colors allow you the freedom to choose from 100 color options, including a limited selection of darker colors formulated to resist warping or buckling when applied to a sound, stable vinyl substrate. <br />• Self-priming One Coat Protection <br />• Low temperature application down to 35° F. <br />• Easy application <br />• Excellent durability and hiding <br />• Resists Blistering and Peeling <br />Color:Most Colors <br />Coverage:250-300 sq. ft. per gallon <br />5.3-6.4 mils wet 2.2-2.7 mils dry, <br />up to 7.0 mils wet; 2.9 mils dry <br />Drying Time, @ 50% RH: <br />@ 35-45°F @ 45°F + <br />Touch:2 hours 1 hourRecoat:24-48 hours 4 hours <br />Drying and recoat times are temperature, humidity, and film <br />thickness dependent <br />Finish:20-30 units @ 85° <br />5-10 units @ 60° <br />Tinting with CCE only: <br />Base:oz. per gallon Strength: <br />Extra White 0-7 SherColor <br />Deep Base 4-12 SherColor <br />Ultradeep Base 4-14 SherColor <br />Light Yellow 4-14 SherColor <br />Extra White K30W00251 <br />(may vary by color) <br />VOC (less exempt solvents): <br />less than 50 grams per litre; 0.42 lbs. per gallon As per 40 CFR 59.406 <br />Volume Solids:42 ± 2% <br />Weight Solids:55 ± 2% <br />Weight per Gallon:10.88 lbs <br />Flash Point:N/A <br />Vehicle Type:Acrylic <br />Shelf Life:36 months unopened <br />Mildew Resistant <br />This coating contains agents which inhibit the growth <br />of mildew on the surface of this coating film. <br />COMPLIANCE <br />As of 08/31/2020, Complies with:OTC Yes <br />OTC Phase II Yes <br />SCAQMD Yes <br />CARB Yes <br />CARB SCM 2007 YesCanadaYes <br />LEED® v4 & v4.1 Emissions N.A. <br />LEED® v4 & v4.1 VOC Yes <br />EPD-NSF® Certified N.A. <br />MIR-Manufacturer Inventory N.A. <br />MPI®Yes <br />APPLICATION <br />When the air temperature is at 35°F, substrates may be colder; prior to painting, check to be sure the air, surface, and material temperature are above 35°F and at least 5°F above the dew point. Avoid using if rain or snow is expected within 2-3 hours. Do not apply at air or surface temperatures below 35°F or when air or surface temperatures may drop below 35°F within 48 hours. <br />No reduction necessary. <br />Brush:Use a nylon-polyester brush.Roller: <br />Use a high quality 3/8-3/4 inch nap synthetic roller cover. <br />For specific brushes and rollers, please refer to our Brush and Roller Guide on sherwin-williams.com <br />Spray—AirlessPressure 2000 p.s.i.Tip .015-.019 inch <br />APPLICATION TIPS <br />Make sure product is completely agitated (mechanically or manually) before use. <br />Thoroughly follow the recommended surface preparations. Most coating failures are due to inadequate surface preparation or application. Thorough surface preparation will help provide long term protection with Duration coating. On repaint work, apply one coat of Duration coating; on bare surfaces, apply two coats of Duration, allowing 4 hours drying between coats. <br />Do not paint in direct sun. Apply at temperatures above 35°F. During application at temperatures above 80°F, Duration sets up quickly. Some adjustment in your painting approach may be required. Paint from a dry area into the adjoining wet coating area. Dries to touch in 1 hour and is ready for service overnight. <br />On large expanses of metal siding, the air, surface, and material temperatures must be 50°F or higher. <br />SPECIFICATIONS <br />Duration Exterior Acrylic Latex is self-priming on most surfaces. Apply 2 coats on new, bare substrates or 1 coat for repaint. <br />Use on these properly prepared surfaces: <br />Aluminum & Aluminum Siding1 <br />Galvanized Steel1 <br />Concrete Block <br />Split face Block <br />Cement Composition Siding/Panels <br />Stucco <br />Concrete <br />Plywood <br />Wood <br />*Vinyl Siding <br />Surfaces with a pH greater than 9 must be primed with a high pH-resistant coating such as Loxon Concrete & Masonry Primer. <br />Standard latex primers cannot be used below 50°F. See specific primer label for that product’s application limitations. <br />Concrete masonry units (CMU) - Surface should be thoroughly clean and dry. Air, material and surface temperatures must be at least 50°F (10°C) before filling. Use Loxon Acrylic Block Surfacer. The filler must be thoroughly dry before topcoating. <br />Knots and some woods, such as redwood and cedar, contain a high amount of tannin, a colored wood extract. If applied to these bare woods, the first coat of DURATION may show some staining, but it will be trapped in the first coat. A second coat will uniform the appearance. If staining persists, spot prime severe areas with 1 coat of Exterior Oil-Based Wood Primer prior <br />to using DURATION. <br />1 On large expanses of metal siding, the air, surface, <br />and material temperatures must be 50°F or higher. <br />08/2020 www.sherwin-williams.com continued on back <br />Appendix F