Duration®
<br />Exterior Acrylic Low Lustre
<br />SURFACE PREPARATION
<br />WARNING! Removal of old paint by sanding, scraping or other means may generate dust or fumes that contain lead. Exposure to lead dust or fumes may cause brain damage or other adverse health effects, especially in children or pregnant women. Controlling exposure to lead or other hazardous substances requires the use of proper protective equipment, such as a properly fitted respirator (NIOSH approved) and proper containment and cleanup. For more information, call the National Lead Information Center at 1-800-424-LEAD (in US) or contact your local health authority.
<br />Remove all surface contamination by washing with an appropriate cleaner, rinse thoroughly and allow to dry. Existing peeled or checked paint should be scraped and sanded to a sound surface. Glossy surfaces should be sanded dull. Stains from water, smoke, ink, pencil, grease, etc. should be sealed with the appropriate primer-sealer. Recognize that any surface preparation short of total removal of the old coating may compromise the service length of the system.
<br />Aluminum and Galvanized Steel:
<br />Wash to remove any oil, grease, or other surface contamination. All corrosion must be removed with sandpaper, wire brush, or other abrading method.
<br />Cement Composition Siding-Panels:
<br />Remove all dirt, dust, grease, oil, loose particles, laitance, foreign material, and peeling or defective coatings. Allow the surface to dry thoroughly. If the surface is new, test it for pH, if the pH is higher than 9, prime with Loxon Concrete & Masonry Primer. After power washing, previously painted masonry may still have a powdery surface that should be sealed with Loxon Conditioner and then apply 1 coat of Duration.
<br />Caulking:
<br />Gaps between windows, doors, trim, and other through-wall openings can be filled with the appropriate caulk after priming the surface. Allow proper drying time before application of the finish.
<br />Concrete, Masonry,Cement, Block:
<br />All new surfaces must be cured according to the supplier’s recommendations—usually about 30 days. Remove all form release and curing agents. Rough surfaces should be filled to provide a smooth surface. If painting cannot wait 30 days, allow the surface to cure 7 days and prime the surface with Loxon Concrete & Masonry Primer. Cracks, voids, and other holes should be repaired with an elastomeric patch or sealant. Concrete masonry units (CMU) - Surface should be thoroughly clean and dry. Air, material and surface temperatures must be at least 50°F (10°C) before filling. Use Loxon Acrylic Block Surfacer. The filler must be thoroughly dry before topcoating.
<br />Composition Board-Hardboard:
<br />Because of the potential for wax bleeding out of the substrate, apply 1 coat of Exterior Oil-Based Wood Primer and then topcoat.
<br />Stucco:
<br />Remove any loose stucco, efflorescence, or laitance. Allow new stucco to cure at least 30 days before painting. If painting cannot wait 30 days, allow the surface to dry 7 days and prime with Loxon Concrete & Masonry Primer. Repair cracks, voids, and other holes with an elastomeric patch or sealant.
<br />SURFACE PREPARATION
<br />Mildew:
<br />Prior to attempting to remove mildew, it is always recommended to test any cleaner on a small, inconspicuous area prior to use. Bleach and bleaching type cleaners may damage or discolor existing paint films. Bleach alternative cleaning solutions may be advised.
<br />Mildew may be removed before painting by washing with a solution of 1 part liquid bleach and 3 parts water. Apply the solution and scrub the mildewed area. Allow the solution to remain on the surface for 10 minutes. Rinse thoroughly with water and allow the surface to dry before painting. Wear protective eyewear, waterproof gloves, and protective clothing. Quickly wash off any of the mixture that comes in contact with your skin. Do not add detergents or ammonia to the bleach-water solution.
<br />Previously Painted Surfaces:
<br />Spot prime bare areas with Duration, wait 4 hours, and paint the entire surface. Some specific surfaces require specialized treatment.
<br />Steel:
<br />Rust and mill scale must be removed using sandpaper, wire brush, or other abrading method. Bare steel must be primed the same day as cleaned.
<br />Unpainted Surfaces:
<br />Duration can be used as a self-priming coating on many bare surfaces. When used this way, the first coat of Duration acts like a coat of primer and the second coat provides the final appearance and performance.
<br />*Vinyl or other PVC Building Products:
<br />Clean the surface thoroughly by scrubbing with warm, soapy water. Rinse thoroughly, if needed prime with appropriate white primer. Do not paint vinyl with any color darker than the original color or having a Light Reflective Value (LRV) of less than 56 unless VinylSafe® Colors are used. If VinylSafe colors are not used the vinyl may warp. Follow all painting guidelines of the vinyl manufacturer when painting. Only paint properly installed vinyl siding. Deviating from the manufacturer’s painting guidelines may cause the warranty to be voided.
<br />Wood, Plywood, Composition Board:
<br />Sand any exposed wood to a fresh surface. Patch all holes and imperfections with a wood filler or putty and sand smooth. All patched areas must be primed.Knots and some woods, such as redwood and cedar, contain a high amount of tannin, a colored wood extract. If applied to these bare woods, the first coat of DURATION may show some staining, but it will be trapped in the first coat. A second coat will uniform the appearance. If staining persists, spot prime severe areas with 1 coat of Exterior Oil-Based Wood Primer prior to using DURATION.
<br />CAUTIONS
<br />For Exterior use only
<br />Protect from freezing
<br />Non-photochemically reactive
<br />Not for use on floors.
<br />Before using, carefully read CAUTIONS on label
<br />ZINC: Use only with adequate ventilation. To avoid
<br />overexposure, open windows and doors or use other
<br />means to ensure fresh air entry during application and
<br />drying. If you experience eye watering, headaches,
<br />or dizziness, increase fresh air, or wear respiratory
<br />protection (NIOSH approved) or leave the area. Avoid
<br />contact with eyes and skin. Wash hands after using.
<br />Keep container closed when not in use. Do not transfer
<br />contents to other containers for storage. FIRST AID:
<br />In case of eye contact, flush thoroughly with large
<br />amounts of water. Get medical attention if irritation
<br />persists. If swallowed, call Poison Control Center,
<br />hospital emergency room, or physician immediately.
<br />WARNING: This product contains chemicals known
<br />to the State of California to cause cancer and birth
<br />defects or other reproductive harm. DO NOT TAKE
<br />INTERNALLY. KEEP OUT OF THE REACH OF
<br />CHILDREN.
<br />HOTW 08/31/2020 K30W00251 09 32
<br />FRC, SP
<br />CLEANUP INFORMATION
<br />Clean spills, spatters, hands and tools immediately after use with soap and warm water. After cleaning, flush spray equipment with compliant cleanup solvent to prevent rusting of the equipment. Follow manufacturer’s safety recommendations when using solvents.
<br />The information and recommendations set forth in this Product Data Sheet are based upon tests conducted by or on behalf of The Sherwin-Williams
<br />Company. Such information and recommendations set forth herein are subject to change and pertain to the product offered at the time of publication.
<br />Consult your Sherwin-Williams representative or visit www.paintdocs.com to obtain the most current version of the PDS and/or an SDS.