Laserfiche WebLink
ATTY/RESO.0012/PC RESO GRANTING APPROVAL OF AN ARC PERMIT FOR 240 TWIN DOLPHIN DR <br />REV: 03-11-2021 PR <br />Page 18 of 21 <br />least one extending to the roof that need to be included in the hydraulic calculations. [COA][FIRE] 71. Fire Department Connections – FDC’s to the fire sprinkler / standpipe systems shall be located at the fire access side of all buildings within 50 feet of a Fire Hydrant on the same side of the road. [COA][FIRE] 72. Fire Alarm System Required – UL Central Station fully addressable fire alarm systems are required in all building meeting NFPA 72. Provide plans and voltage drop calculations for the design of these systems. [COA][FIRE] 73. Premises Identification (Addressing Numbers)– Indicate on the plan where the premises identification (address) will be located and the size (minimum 12”) in a contrasting background facing the street from which the building takes the address. CFC 505. [COA][FIRE] 74. Gurney Elevator Requirements – Elevators in buildings that are four stories or more shall provide for fire department emergency access to all floors. At least one elevator car in each building shall be of such a size and arrangement to accommodate an ambulance gurney 24 inches by 84 inches with not less than 6-inch radius corners, in the horizontal, open position and shall be identified by the international symbol for emergency medical service. The symbol shall not be less than 3 inches high and shall be placed inside on both sides of the hoist-way door frame CBC 3002.4. [SDR][BUILDING] 75. Fire Requirements – All of the requirements of the Redwood City Municipal Code Section 12.23 need to be incorporated into the building with the exception of the Firefighter’s Communication System as this project is required to install an approved ERRCS. The requirements include Emergency Planning signage, Public Address System, and Fire Equipment Cache rooms. [COA][FIRE] 76. Portable Fire Extinguishers Required – Portable fire extinguishers, with a minimum classification of 2A:10BC are required are required to be permanently installed in all buildings within 75 feet of travel from all portions of the building in compliance with NFPA 10 and CFC 906. [COA][FIRE] Construction-Related Activities 77. Verification for Dimensions – All dimensions, including building location on the site, setbacks, building height, etc. shall be verified by a licensed surveyor. A survey report shall be provided to the Building Inspector for review and approval. [COA][BUILDING] 78. Sales and Use Taxes – Applicant shall use good faith efforts to register with the Board of Equalization to create an ID prior to project construction and operation. This maximizes the City’s allocation of sales and use taxes associated with project construction. Contact Nancy Murguia, Finance Department, at (650) 780-7097 or nmurguia@redwoodcity.org. [COA][FINANCE] 79. Hours of Construction – On-Site Construction activity is permitted between 7:00 a.m. and 8:00 p.m. Monday through Friday, except as permitted on weekends by the Building Official, and shall adhere to the City’s Noise Ordinance. If possible, the noisiest construction activities would be scheduled for daytime hours when the ambient noise levels are highest. [SDR][BUILDING]