My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
Reso PC22-15 0115 PC Reso Approving Project with Draft Conditions of Approval 557 E. Bayshore Road
RedwoodCity
>
City Clerk
>
Resolutions
>
Planning Commission
>
2022
>
Reso PC22-15 0115 PC Reso Approving Project with Draft Conditions of Approval 557 E. Bayshore Road
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/31/2024 11:41:58 AM
Creation date
7/31/2024 11:41:49 AM
Metadata
Fields
Template:
CC Index
CC Index - Document Type
Resolution
Date
12/13/2022
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
ATTY/RESO.0115/PC RESO APPROVING PROJECT WITH DRAFT CONDITIONS OF APPROVAL - 557 E. BAYSHORE ROAD <br />REV: 12-21-2022 VR <br />Page 23 of 26 <br />d. The requirement for emergency escape and rescue windows and therefore ladder <br />pads may be eliminated if a more fire resistive construction type such as Type IIIA as well <br />as an NFPA 13 compliant fire sprinkler system is utilized. <br /> <br />75. Available Water Supply to Project Site - Provide current fire flow information from the <br />water purveyor to indicate the maximum available water flow in gallons per minute (GPM) at a <br />minimum of 20 pounds per square inch (psi) residual pressure. This information must be dated <br />within six months. [COA][FIRE] <br /> <br />76. Fire Hydrants - Based on the required fire flow for this project, the number of fire <br />hydrants and the required distance between them and to the property lines will be determined <br />utilizing Appendix C of the CFC. [COA][FIRE] <br /> <br />77. Automatic Fire Sprinkler / Automatic Wet Standpipe Systems Required – As the <br />proposed buildings are four or more stories in height all of the buildings and garage areas are <br />required to be equipped with automatic wet standpipe / fire sprinkler systems. Provide plans and <br />hydraulic calculations for the design of these systems. The plans shall also indicate on-sight <br />exterior automatic wet standpipe connections and interior automatic standpipe connections in <br />all of the buildings stairwells on the intermediate landings with one extending to the roof that <br />need to be included in the hydraulic calculations. [COA][FIRE] <br /> <br />78. Fire Department Connection – FDC’s to the fire sprinkler / standpipe systems shall be <br />located at the fire access side of all buildings within 50 feet of a Fire Hydrant. [COA][FIRE] <br /> <br />79. Fire Alarm Systems Required – UL Central Station monitored fully addressable fire alarm <br />systems are required in all buildings meeting NFPA 72. Provide plans and voltage drop <br />calculations for the design of these systems. [COA][FIRE] <br /> <br />80. Premises Identification (Address Numbers) - Indicate on the plans where the premises <br />identification (address) will be located and the size (minimum 12”) illuminated with a contrasting <br />background facing the street from which the building takes the address CFC 505. [COA][FIRE] <br /> <br />81. Gurney Accommodating Elevator Requirement -– Elevators in buildings that are four <br />stories or more shall provide for fire department emergency access to all floors. At least one <br />elevator car in each building shall be of such a size and arrangement to accommodate an <br />ambulance gurney 24 inches by 84 inches with not less than 6-inch radius corners, in the <br />horizontal, open position and shall be identified by the international symbol for emergency <br />medical service. The symbol shall not be less than 3 inches high and shall be placed inside on both <br />sides of the hoist-way door frame CBC 3002.4. [COA][FIRE] <br /> <br />82. Portable Fire Extinguishers Required - Portable fire extinguishers, with a minimum <br />classification of 2A:10BC are required to be permanently installed in all buildings within 75 feet <br />of travel from all portions of the building in compliance with NFPA 10 and CFC 906. [COA][FIRE]
The URL can be used to link to this page
Your browser does not support the video tag.