My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
Reso 23-21 0097 PC23-21 PC Reso 1 Twin Dolphin
RedwoodCity
>
City Clerk
>
Resolutions
>
Planning Commission
>
2023
>
Reso 23-21 0097 PC23-21 PC Reso 1 Twin Dolphin
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/21/2024 2:47:17 PM
Creation date
10/21/2024 2:47:09 PM
Metadata
Fields
Template:
CC Index
CC Index - Document Type
Resolution
Meeting Type
Regular
Agency Type
Planning Commission
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
ATTY/RESO.0097/PC RESO 1 TWIN DOLPHIN <br />REV: 10-04-23 VR <br />Page 18 of 23 <br />provide plans and hydraulic calculations under a separate fire permit for the design of the fire <br />sprinkler system. [COA][FIRE] <br /> <br />52. Fire Alarm System - An Underwriters Laboratories Central Station fully addressable fire alarm <br />system is required to be installed throughout the building and in compliance with NFPA 72. The fire <br />alarm system must also be provided with Underwriters Laboratories Central Station Monitoring <br />Service. Prior to installation, provide plans and voltage drop calculations under a separate fire <br />permit for the design of the fire alarm system and identify the company providing the Underwriters <br />Laboratories Central Station Monitoring Service. [COA][FIRE] <br /> <br />53. Means of Egress Sizing and Emergency Voice/Alarm Communication System - The means of egress <br />sizing must use the capacity factor of 0.2 inches per occupant for the stairways and 0.15 inches per <br />occupant for other egress components. These capacity factors are permitted to be applied when <br />the building is provided with fire sprinkler protection and an emergency voice/alarm <br />communication system throughout the building. [COA][FIRE] <br /> <br />54. Emergency Responder Radio Coverage System (ERRCS) - An emergency responder radio coverage <br />system (ERRCS) is required. [CFC §510.1] The plans for this system must be submitted under a <br />separate fire permit prior to installation. These plans should show that the room in which the ERRCS <br />head-end unit is installed has independent ventilation or air conditioning to protect against <br />overheating of the communications equipment. The air conditioning system must be capable of <br />maintaining temperatures within the range established for the communications equipment. An <br />acceptance test of the system must be provided upon completion of installation and prior to <br />building occupancy. [CFC § 510.5.3] [COA][FIRE] <br /> <br />55. Fire Apparatus Access Roads - An approved fire apparatus access road must be provided. A Class I <br />automatic wet standpipe system, at the location shown in the Approved Alternate Means and <br />Methods Request (AMMR) application, signed January 19, 2023, was approved as an alternate <br />method for compliance. [CFC §503.1.1]. The approved AMMR shall be placed on the plans prior to <br />the building permit application. [COA][FIRE] <br /> <br />56. Aerial Fire Apparatus Access - Buildings greater than 30 feet in height require aerial (ladder truck) <br />fire apparatus access, positioned parallel to the long side of the building. No overhead utility or <br />power lines, horizontal or vertical fixed obstructions are to be located along the aerial fire apparatus <br />access road, nor can they be located between the aerial fire apparatus access road and the building <br />that may obstruct aerial fire apparatus operations. [CFC Appendix D§105.1]. [COA][FIRE] <br /> <br />57. Required Fire Flow - Based on the proposed construction type of Type I-B, 215,234 square feet <br />(Combined Levels 1, 2, and 3), the required fire flow for this project is 5,250 GPM at 20 psi residual <br />pressure. After allowing for a 50% reduction due to the installation of automatic fire sprinklers <br />meeting section 903.3.1.1 of the 2019 CFC (NFPA 13), the required fire flow for this project is 2,625 <br />GPM at 20 psi residual pressure. [CFC §507.1] Based on the required fire flow of 2,625 GPM at 20 <br />psi residual pressure, the required number of fire hydrants is three (3) with a spacing of 450 feet in <br />accordance with Appendix C of the CFC. [COA][FIRE] <br /> <br />58. Class I – Automatic Wet Standpipe Hose Station Outlets - Automatic wet standpipes are required <br />to be provided as addressed in the Approved AMMR, signed January 19, 2023, to be installed on <br />the Podium Plaza, throughout the parking garage, and in all stairways on the intermediate stair
The URL can be used to link to this page
Your browser does not support the video tag.