ATTY/RESO.0022/PS RESO 77 BIRCH STREET – EXHIBIT A <br />REV: 05-16-24 VR <br />Page 7 of 10 <br />listing of source control and site design measures to be implemented at the site; saturated <br />hydraulic conductivity rate(s) at relevant locations or hydrologic soil type (A, B, C or D) and <br />source of information; elevation of high seasonal groundwater table; and a brief summary <br />of how the project is complying with Provision C.3 of the MRP. [COA][ENGINEERING] <br />36. Stormwater BMPs - Stormwater Pollution Prevention Program Best Management Practices <br />(BMPs) for construction shall be implemented to protect water quality, in accordance with <br />the approved Stormwater Pollution Prevention Plan (SWPPP). BMP plan sheets are <br />available electronically for inserting into project plans. [SDR][ENGINEERING] <br />Street Infrastructure Improvements <br />37. Green Infrastructure Improvements - A bio-retention area shall be included in the project <br />frontage along Birch Street sized to treat the half-street tributary area of the project <br />frontage up to centerline of Birch Street. [SDR][ENGINEERING] <br />38. Repair or Replace Street Infrastructure - Restore streets surrounding the project site to the <br />satisfaction of the City Engineer at project completion. When this requires additional <br />pavement restoration, the Engineer shall approve the preferred layout of pavement <br />markings. [SDR][ENGINEERING] <br /> <br />Fire and Safety <br />39. Radio Coverage for Emergency Responders – All building and parking garages shall have <br />approved radio coverage for emergency responders within the building. Upon completion <br />of the building construction, a radio coverage test shall be conducted per the applicable <br />codes and standards and if the test fails an Emergency Responders Radio Coverage System <br />shall be installed. Verify any Blue Box phone communication requirements with the <br />Redwood City Police Department. [COA][POLICE] <br />40. Addressing and Access – The following requirements apply: [COA][FIRE] a. Addresses must be logical, sequential numbers, i.e. First Floor 101, 102, 103, <br />Second Floor 202, 203, 204, as opposed to F303, G401, etc. b. Floor plan maps shall be submitted with unit numbers at all entrances, excluding <br />fire exits. c. Provide a key pad with 24-hour access code for public safety personnel at the main <br />entrance, as opposed to just RFID readers or similar devices. <br />41. Elevator Requirements – The following requirements for elevators apply: [SDR][BUILDING] a. One elevator shall be available for use as an accessible means of egress in case of <br />emergency. b. One elevator shall be connected to backup generator power in order to remain <br />operable during emergencies. This elevator shall be provided with appropriate