My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
Reso25 16298
RedwoodCity
>
City Clerk
>
Resolutions
>
City Council
>
2020-2029
>
2025
>
Reso25 16298
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/29/2025 4:06:01 PM
Creation date
4/29/2025 4:05:01 PM
Metadata
Fields
Template:
CC Index
CC Index - Document Type
Resolution
Date
4/28/2025
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
155
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
<br /> <br /> <br />65 <br /> subgrade preparation for interior and exterior concrete slabs-on-grade; <br /> flexible (asphalt concrete) and rigid (concrete) pavement sections; <br /> 2019 and 2022 California Building Code (CBC) site class and design spectral response acceleration parameters; <br />and <br /> construction considerations. <br />The geotechnical report (p. 14) concludes: “We conclude that from a geotechnical engineering standpoint, the site can <br />be developed as planned, provided the recommendations presented in the attached report are incorporated into the <br />project plans and specifications and implemented during construction.” <br />The current geotechnical report prepared for the project component, including any subsequent revisions, and any <br />subsequent detailed excavation, earthwork, and foundation plans are subject to City review and approval. In <br />collaboration with a California Registered Geotechnical Engineer, the appropriate City staff would also observe onsite <br />construction work. These conclusions are consistent with the California Building Code (CBC), the California <br />Historical Building Code (CHBC), and both the DTPP program EIR (Chapter 16, Geology and Soils) and the DTPP <br />Plan-Wide Amendments program SEIR (Chapter 16, Geology and Soils). The Commercial Component would not <br />create new impacts or increase impacts, and there is no new information of substantial importance for CEQA purposes. <br />iv) The Commercial Component site is relatively flat; no impacts from landslides are anticipated. <br />The Downtown Precise Plan program EIR concluded that while the DTPP area could be subject to moderate to high <br />susceptibility to ground shaking and liquefaction, the City’s standard grading and building permit regulations provide <br />reasonable assurances that individual projects would incorporate the design and engineering refinements necessary to <br />reduce the potential impact of DTPP-facilitated development to less than significant, requiring no additional <br />mitigation. The DTPP Plan-Wide Amendments program SEIR affirmed this conclusion. The site-specific <br />geotechnical report prepared for the Commercial Component, and any subsequent revisions, is subject to City review <br />and approval, consistent with the CBC and/or CHBC, and both the DTPP program EIR (Chapter 16, Mitigation <br />Measure 16-1) and the DTPP Plan-Wide Amendments program SEIR (Chapter 16, Geology and Soils) findings. <br />Because the Commercial Component would have a less-than-significant impact with compliance with the regulatory <br />framework and incorporation of standard project conditions, this component would be consistent with the analysis <br />within the DTPP EIR and Plan-Wide Amendments SEIR. The Commercial Component would not create new impacts <br />or increase impacts and there is no new information of substantial importance for CEQA purposes. <br />b. The DTPP EIR found that the DTPP would create a potentially significant impact as it relates to erosion and <br />sedimentation due to the ground disturbance associated with future developments, requiring mitigation. DTPP EIR <br />Mitigation Measure 16-3 was identified to reduce this impact to a less-than-significant level by requiring the <br />preparation of an erosion control plan for all future developments involving grading 10,000 square feet or more, <br />consistent with the state Construction General Permit and its required SWPPP. The DTPP Plan-Wide Amendments <br />program SEIR (pp. 16-10 and 16-11) concurred with the DTPP EIR conclusion and includes Mitigation Measure <br />GEO-2, which restates Mitigation Measure 16-3 from the DTPP Final EIR with minor text revisions (“clarifying <br />amendments”). This mitigation measure, which shall be required as a condition of approval for the Commercial <br />Component, shall be implemented during construction and would reduce the potentially significant impacts on soil <br />erosion and sedimentation to a less-than-significant level. <br />The Commercial Component will be subject to DTPP program EIR Mitigation Measure 16-3, which shall be required <br />as a condition of approval. Mitigation Measure 16-3 requires the applicant to prepare an erosion control plan subject <br />to City approval and consistent with the required San Mateo County Stormwater Pollution Prevention Plan (SWPPP) <br />Best Management Practices. As a result, the proposed Commercial Component would have a less-than-significant <br />impact. The Commercial Component would not create new impacts or increase impacts and there is no new <br />information of substantial importance for CEQA purposes. <br />c. The DTPP Final EIR concluded that the risks associated with unstable geologic units or soil are low, but that effects <br />of strong seismic ground shaking and liquefaction would present a potentially significant impact. The DTPP Plan- <br />Wide Amendments program SEIR concluded that complying with the regulatory framework would ensure that new <br />structures would not be susceptible to the effects of unstable geologic units and soils, so the impacts would be less <br />than significant. <br />No changes to geologic substructures are expected to occur as a result of Commercial Component implementation. <br />As described in item (a) above, the proposed Commercial component would comply with all applicable local and State <br />codes and regulations, and this component design would incorporate City-approved geotechnical recommendations <br />ATTY/RESO.0031/CC RESO CEQA GUIDELINES (901 EL CAMINO REAL) <br />REV: 04-22-25 VR <br /> <br />Page 65 of 148
The URL can be used to link to this page
Your browser does not support the video tag.