REV: 04-29-25 LF <br />LINE VOLTAGE OUTLET L-3 <br />The L-3 body compartment shall be equipped with the following receptacle(s), located on the <br />forward wall of the compartment. <br />A total of one (1) shall be provided. <br />RECEPTACLE TYPE <br />The receptacle(s) shall be type NEMA 5-20 120V/20A duplex receptacle with a cover. <br />RECEPTACLE POWER <br />The previously described outlet(s) shall be powered by the shoreline connection or the on-board <br />AC generator through the automatic transfer switch described elsewhere within these <br />pecifications. <br />SIDE SCENE LIGHT LOCATION <br />There shall be two (2) scene lights installed on top of the body, one (1) each side, at the rear body <br />corners. <br />MINI TRIPOD SCENE LIGHT <br />Whelen model PFP1AP1 series LED lights with model 3300 series demountable, portable tripod <br />mounting assemblies shall be provided. The base shall be cast aluminum with three legs for <br />stability. A 12” pigtail ending with a male L5-15 twist lock plug shall be provided for each light. <br />Wiring shall extend from the lower side of the lighthead. <br />The 75 watt, 120v AC Pioneer lighthead shall measure 9.75 inches high by 10.81 inches wide by <br />6.06 inches deep. The lighthead shall produce 10,000 usable lumens and have an amp draw of <br />0.6 amps. have an on/off switch and a heat-resistant handle. The lamp head, switch box, mounting <br />arm and base legs shall be powder coated. The LED scene light shall be for fire service use. <br />PORTABLE LIGHT RECEPTACLE(S) <br />One (1) receptacle shall be located at each portable light location specified. <br />There shall be a total of two (2) receptacle(s) provided. <br />RECEPTACLE TYPE <br />The receptacle(s) shall be type NEMA L5-15 120V/15A twist lock single receptacle with a weather <br />resistant cover. <br />RECEPTACLE POWER <br />The previously described outlet(s) shall be powered by the on-board AC generator and shall be <br />live when the generator is in operation. <br />ATTY/AGR.2025.089/Fire Apparatus Solutions (Purchase of Spartan-LTC 105' TDA) (Page 114 of 150)