Laserfiche WebLink
3. Specification Section 32 18 13 — Synthetic Turf Playing Field (Fair Oaks), page 32 18 13 - 11 has <br />been removed and is being replaced in orderto clarify Port 12.03-A.5. The training seminar by the <br />Contractor will utilize the Owner's existing groomer / sweeper; new equipment is not required. <br />4. Specification Section 32 18 14 — Synthetic Turf Base (Fair Oaks), page 32 18 14 - 8 has been <br />removed and is being replaced in order to clarify Part 2, 1.06-A. The shock/drain pad shall be <br />YSRHD by Brock USA, or approved equal. <br />See attached revised specification pages. 32 18 13 — 6 (Mitchell), 32 18 13 — 5 & 11 (Fair Oaks), and, 32 <br />1814 — 8 (Fair Oaks). <br />QUESTIONS AND ANSWERS <br />1. For the Mitchell and Fair Oaks turf project are you open to looking at other turf system options <br />besides Fieldturf? Any substitution requests should be made using Document 00 6325 from the <br />specifications package. Here is the link to our bid advertisement: Mitchell & Fair Oaks Field <br />Synthetic Turf Replacement Project. Based on a review of the substitution requests received, <br />the following turf products are accepted "as equal": <br />a. Shaw Sports Turf —Legion 2.0 <br />2. For the Mitchell and Fair Oaks turf project are you open to looking at other turf system options <br />besides Fieldturf? Any substitution requests should be made using Document 00 6325 from the <br />specifications package. Here is the link to our bid advertisement: Mitchell & Fair Oaks Field <br />Synthetic Turf Replacement Proiect. Based on a review of the substitution requests received, <br />the following turf products are not accepted, for the reasons noted: <br />a. Hellas Construction — Matrix Helix: not dual-fibered; refer to specification section 32 18 <br />13. <br />b. Hellas Construction — Soteria: compatibility issue with existing pad; refer to specification <br />section 32 18 14. <br />c. Hellas Construction — EcoCork: does not meet revised cork specification; refer to <br />specification section 32 1813. <br />d. Shaw Sports Turf — Cork and sand infill: insufficient information provided; refer to <br />specification section 32 1813. <br />3. For the Mitchell and Fair Oaks turf project are you open to looking at other turf system options <br />besides Fieldturf? Any substitution requests should be made using Document 00 6325 from the <br />specifications package. Here is the link to our bid advertisement: Mitchell & Fair Oaks Field <br />Synthetic Turf Replacement Project. The following turf product substitution requests were <br />received but were not considered, for the reasons noted: <br />a. Act Global Americas—XtremeTurf: received too late; refer to specification section 00 21 <br />13. <br />City of Redwood City 1017 Middlefield Road, Redwood City, CA. 94063 Tel: 650-780-7380 www.rgdwoodeFty.org <br />2 <br />