ATTY/RESO.0080/PC RESO 590 VETERANS & 91 WINSLOW PROJECT – EXHIBIT A - COA <br />REV: 11-14-24 JB <br />Page 13 of 19 <br />officers, or other City enforcement personnel according to specifications approved by the <br />Fire Prevention Bureau. Controls for, and access to, such system must be installed on the <br />ground floor of the building at a location subject to the approval of the fire code official. <br />[CFC 907.2.12.3.1-C and Redwood City Code of Ordinances §12.23] A separate public <br />address system is not required to be installed when an Emergency Voice Alarm <br />Communication System (EVACS) is installed throughout per CFC 907.5.2.2, to fulfill the <br />requirements of the Public Address System. <br /> <br />65. Elevator Lobbies and Waiting Areas – Two-Way Communication System: The elevator <br />lobbies and waiting areas must be provided with a two-way communication system as <br />required by CFC §1009.8. <br /> <br />66. Public Safety Key Boxes: Approved Knox® key boxes must be located adjacent to the <br />building entrance. [CFC §506.1] The public safety key boxes must be recessed and <br />installed adjacent to each entrance within 60 to 72 inches of the finished walking surface. <br />Each public safety key box must contain four sets of keys, with each set containing a key <br />for building access, fire equipment room access, fire cache room, elevator keys, utility <br />room keys and other keys essential for emergency operations. <br /> <br />67. Elevator Car to Accommodate Ambulance Stretcher: All buildings with one or more <br />passenger service elevators must be provided with not less than one medical emergency <br />service elevator to all landings meeting the provisions of CBC Section 3002.4a. <br /> <br />68. Portable Fire Extinguishers: Portable fire extinguishers, with a minimum classification of <br />2A:10B:C are required to be permanently installed throughout all buildings within 75 feet <br />of travel from all portions of the building in compliance with CFC 906 and NFPA 10. <br /> <br />69. Premise Identification - Address Numbers: All buildings must be provided with address <br />identification that is legible and placed in a position that is visible from the street or road <br />facing the street from which the building takes the address, numbers to be a minimum <br />size of 12-inch in height, with contrasting background, and all address numbers to be <br />illuminated and visible from the street during darkness. [CFC 505.1] [CFC Section 505.1 <br />and City of Redwood City Code, Ordinances Section 9.48] <br /> <br />70. Construction Egress and Standpipes: During construction when building construction <br />exceeds 40 feet in height above the lowest level of fire department vehicle access a <br />temporary or permanent stairway must be provided, and as construction progresses, the <br />stairway must be extended to within one floor of the highest point of construction, having <br />secured decking or flooring, and not less than one Class I standpipe must be provided for <br />use, and the standpipe must be installed prior to construction exceeding 40 feet in height <br />above the lowest level of fire department vehicle access, with the standpipe provided <br />with fire department hose connections at locations adjacent to the stairways and must