My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
Agmt26 Ensight Technologies, LLC - PARCS System
RedwoodCity
>
City Clerk
>
Agreements
>
2020-2029
>
2026
>
Agmt26 Ensight Technologies, LLC - PARCS System
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/23/2026 4:18:18 PM
Creation date
1/23/2026 4:15:24 PM
Metadata
Fields
Template:
Agreement
RMP File Number
304
Date
1/16/2026
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
167
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
REV: 01-05-26 LR <br />f. Validation management feature as part of MMS, as further described <br />below. <br />g. Permit Parker management feature as part of MMS <br />h. Standard payment mode is to be pre-payment for parking for a <br />selected duration of time either prior to arrival (via mobile app) or upon <br />arrival within a defined grace period. <br />i. Static payment instructional signage, as defined below and on <br />Drawings. <br />j. Fixed LPR System integration as further defined below and in the <br />related Fixed LPR Specification. <br />k. PbC System integration, including supporting both app-based <br />payment and text-to-pay payment, as further described below. <br />l. Integration with Owner’s TurboDataTM Citation Management System <br />(CMS), as defined below. <br />m. Furnish and install one (1) proximity card reader on the entry lane of <br />the Winslow Garage, as shown in Drawings. Provide the capability to <br />program the proximity card to provide access control to the Winslow <br />Garage, including control of the existing rolling overhead door when <br />that door is in the “down” position. See further description of the <br />required functionality below. <br />n. Furnish and install all necessary “headend” components such as <br />servers, controllers, network switches, and UPS units, as further <br />detailed below. <br />o. All necessary components and materials for a complete and <br />functioning turnkey MSM system as identified in this specification. <br />1.4 DESIGN CRITERIA <br />A. Accuracy: Provide the following minimum accuracy levels. Calculate accuracy <br />by dividing the accurate counts/calculations by all counts/calculation. <br />1. Fee calculation: 100% <br />2. Revenue amounts: 100% <br />3. Data received and accepted by computer system as valid: 100% <br />4. Data transmission: Less than one message re-transmission per hour. <br />B. Equipment Construction: Design and construct all components and equipment <br />with the following: <br />1. Durable vandal and weather resistant cabinets, which maintain finish, look, <br />integrity and functionality in the environment in which installed for a period <br />of ten years. <br />a. Mounting holes accessible only from inside of cabinets. <br />b. Hinged cabinet doors that swing clear of bollards, walls, columns, and <br />any other obstructions. <br />ATTY/AGR.2026.001/EnSight Technologies (Parking Access and Revenue Control System (PARCS)) (Page 32 of 167)
The URL can be used to link to this page
Your browser does not support the video tag.