Laserfiche WebLink
SECTION 16500 <br /> SIGNALS, LIGHTING AND ELECTRICAL SYSTEMS <br /> PART I - GENERAL <br /> 1.01 WORK INCLUDED <br /> A. Installation of electroliers and appurtenances. <br /> B. Installation of traffic signal standards, posts, cabinets, and foundations. <br /> C. Traffic signal heads, push button assemblies, luminaries, hardware and appurtenances. <br /> D. Conduit, circuits, and appurtenances. <br /> E. Trenching for conduits and appurtenances, and backfill. <br /> F. Traffic Signal controller assembly. <br /> G. Installation of electrical service, service cabinet, circuits and connections to existing circuits. <br /> H. Battery Backup System. <br /> I. Dust alleviation and control. <br /> J. Cleanup and restoration of surface in improved areas, including pavement markings and signage. <br /> K. Supplying all labor, materials, equipment and apparatus not specifically mentioned herein or noted on the <br /> plans, but which are incidental and necessary to complete the work specified. <br /> 1.02 APPLICABLE PUBLICATIONS <br /> A. The publications listed below form a part of this specification to the extent referenced. The publications <br /> are referred to in the text by the general designation only. <br /> 1. The State of California, Department of Transportation Standard Specifications, Standard Plans, <br /> and Manual on Uniform Traffic Control Devices (MUTCD). <br /> 2. NEC — The National Electric Code. <br /> 3. California Division of Industrial Safety Electrical Orders (Title 8). <br /> 4. I.E.S. — Illumination Engineering Society of Standards. <br /> 5. NEMA — National Electrical Manufacturers Association Standards. <br /> 6. IMSA — International Municipal Signal Standards and Specifications. <br /> 7. SPUC Electrical Safety Orders (i.e., General Order No. 95) <br /> 8. American Society for Testing and Materials (ASTM) Publications: <br /> A —123 Zinc Coatings, Rolled, Pressed Forged Mat. <br /> A - 307 Carbon Steel Bolts and Studs, 60,000 psi Tensile Strength. <br /> B - 3 Specification for Soft or Annealed Copper Wire. <br /> B - 8 Cubic Conduit Hard Medium Soft. <br /> D —1785 Pipe, Poly Vinyl Chloride (PVC) Plastic, Schedules 40, 80 &120. <br /> 1.03 SUBMITTALS <br /> A. Contractor shall submit shop drawings on all electroliers, fixtures, and signal system equipment <br /> components, and catalogue cuts of conduits, conductors, pull boxes, and other equipment for approval <br /> prior to ordering material and equipment. <br /> B. Traffic Control Plan: When work will occur on or adjacent to the right -of -way, submit a Traffic Control Plan <br /> is accordance with Section 01550 72 hours in advance for approval prior to starting work. <br /> 1.04 QUALITY ASSURANCE <br /> A. All work shall be done under the supervision of, and to the satisfaction of the City Engineer. <br /> SIGNALS LIGHTING AND ELECTRICAL SYSTEMS 16500 -1 <br /> EMERGENCY VEHCILE PREEMPTION PROJECT 2010 <br />