My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
Agmt11 Pacific Electric Contracting Inc.
RedwoodCity
>
City Clerk
>
Agreements
>
2010-2019
>
2011
>
Agmt 11 Under 60K
>
Agmt11 Pacific Electric Contracting Inc.
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/7/2011 1:09:02 PM
Creation date
3/7/2011 1:08:54 PM
Metadata
Fields
Template:
Agreement
Contractor Name
Pacific Electric Contracting Inc.
PROJECT NAME
Emergency Vehicle Preemption Project (2010) Jefferson Avenue-Marshall Street, Redwood City
RMP File Number
304.5
Date
3/7/2011
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
60
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
D. Conductors shall be UL listed and rated for 600 volt operation. <br /> E. Conductors shall be spliced by the use of "C" shaped compression connectors as shown on the Standard <br /> Plans. <br /> F. Traffic Signal Cable, 12 Conductor No. 14 AWG stranded (600 volt class) and meeting IMSA <br /> Specification 20 -1 -1984, may be used in lieu of individual wires. <br /> G. Insulation for conductors shall be one of the following: <br /> 1. Type RHH or RHW cross - linked polyethylene. <br /> 2. Type THW OR THWN Poly Vinyl chloride. <br /> 3. At any point, the minimum thickness of any Type THWN insulation shall be 13 mils for conductor <br /> sizes No. 14 and No. 12, 18 mils for conductor size No. 10, 27 mils for conductor sizes No. 8 and <br /> No. 6, and 36 mils for conductor sizes No. 4 and No. 2. At any point, the minimum thickness of <br /> the nylon jacket shall be 4 mils for conductor sizes No. 14 to No. 10, inclusive, 5 mils for <br /> conductor sizes No. 8 and No. 6, and 6 mils for conductor sizes No. 4 and No. 2. <br /> 2.09 LUMINAIRES AND BALLASTS <br /> A. Luminaires shall be high pressure sodium vapor luminaries of the voltage, type and wattage shown on <br /> the plans, and shall be in conformance with all requirements in Section 86 -6.01 "High-Pressure Sodium <br /> Luminaries" of the Standard Specifications, and these provisions. <br /> B. Ballasts shall conform to all of the provisions in Section 86 -6.01 "High- Pressure Sodium Lamp Ballasts ", <br /> of the Standard Specifications, and these provisions. <br /> C. Hardware shall be stainless steel or cadmium plated. Machine screws or bolts shall be used to secure <br /> removable components. Sheet metal screws shall not be used. <br /> D. The lamp socket shall be of high temperature, flame retardant thermoset material with self- wiping <br /> contacts or may be of other equally durable material. The socket shall be rated for 660 watts and 1,000 <br /> volts. <br /> E. Ballasts for luminaries to be mounted on mast arms, brackets or lowering assemblies shall be located <br /> within the luminaire housing. The ballast for each horizontally mounted luminaire shall consist of <br /> components mounted on the luminaire housing, components mounted on a metal plate secured to the <br /> house, or components mounted on a down opening door. The door shall be hinged and secured to the <br /> luminaire housing separately from the refractor of flat lens frame. The door shall be easily removable and <br /> replaceable. The door shall be secured to the housing in a manner to prevent its accidental opening <br /> when the refractor of flat lens frame is opened. <br /> F. Ballasts for luminaries to be mounted on mast arms, brackets, or lowering assemblies shall be the <br /> regulator, non - regulating reactor, autotransformer, or high reactance type. <br /> G. Section 86-6.01A (1), "Regular Type Ballasts ", shall be lag -type regulator type ballasts. <br /> H. The 12th paragraph in Section 86 -6.10, "High- Intensity- Discharge Lamp Ballasts" of the Standard <br /> Specifications is amended to read: <br /> "Ballasts for luminaires shall be located within the luminaire housing. The ballast for each <br /> vertically mounted luminaire shall consist of components mounted in the luminaire <br /> housing and components mounted on a metal plate secured to the pole." <br /> I. Luminaries shall be the semi - cutoff type with a Type IV distribution. <br /> J. Fused splice connectors shall conform to the provisions in Section 86 -2.095 "Fused Splice <br /> Connectors" of the Standard Specifications, and these provisions. <br /> K. Each street light shall have an individual spliced fused connector located in the pull box adjacent <br /> to the pole. <br /> L. All fixture housings shall be painted in accordance with section 2.02 "Painting" of these <br /> specifications. <br /> SIGNALS LIGHTING AND ELECTRICAL SYSTEMS 16500 -5 <br /> EMERGENCY VEHCILE PREEMPTION PROJECT 2010 <br />
The URL can be used to link to this page
Your browser does not support the video tag.