Laserfiche WebLink
1 <br /> � EXHIBTT �8�� 8 � � � I I <br /> ON BROADWAY - PARKING GARAGE <br /> CLARIFICATIONS & EXCLUSIONS <br /> 6of8 <br /> • 3ound or intercom system is excluded. <br /> — • Bond for misc. s eciait subcontractor is excluded. <br /> 10160 TOILET • Included Bobrick or similar toilet accessories at Attendant's O <br /> ACCESSORIES & that includes surface mounted grab bar, seat cover dispenser, <br /> PARTIONS combination TP & sanitary na,�kin disposal, mirror, PT & was <br /> disposal. <br /> • Toilet partitions are excluded. <br /> • Bond for toilet accessor subcontractor is excluded. <br /> 10430 SIGNAGE • Inciuded an Allowance of $40.000 for way findin / si na e. <br /> 10538 AWIVINGS • Not used. <br /> 11500 PARKING ACCESS • Pazking and access control systems aze excluded. <br /> CONTROL <br /> SYSTEM <br /> 14200 ELEVATORS • Provide 2 EA — 3 stop holeless, 3,500 #, 150 FPM elevators fc <br /> gazage. <br /> • Included an Allowance of $25,000 for finishes. <br /> • Bond for elevator subcontract is included. <br /> 15400 DESIGN BUILD • Provided a 500 gailon sand / oil sepazator. <br /> PLUMBING • Provided RI & vim for plumbing at Attendant toilet. <br /> • Provided elevator sump pumps & pit drains. <br /> • Provided garape sump pump for gazage area drains only. <br /> • Provided 24 EA �azage area drains 1 EA trench drain & 9 EA <br /> drains. <br /> • Provided 4 EA hose bibs. <br /> • Wall hydtants / hose bibs at stairways or interior columns are <br /> excluded. <br /> -- • Plumbing to be Design / Build. <br /> • Bond for Plumbin� subcontractor is included. <br /> 15500 DESIGN BUILD • Assume sufficient flow and pressure provided by City water s <br /> FIRE • Provide backflow preventors on the inside of building, sufficia <br /> PROTECTION space to be allowed for backflow to be provided in design of E <br /> • Provide FDC on street ]evel. <br /> • Garage heads [o be extended coveraLe upright heads. <br /> • Fire hoses, hose valves and cabinets are excluded. <br /> • Fire pumps are excluded. <br /> • System desi�ned to meet NFPA codes and excludes any Factc <br /> Mutual or other ratings agency requirements or review. <br /> • Bond for Fire Procection subcontractor is included. <br /> 1�800 DESIGN BUILD . Provided fully ducted exhaust system at rate of 1.5 CFM / SF <br /> HVAC centrifugal exhaust fans with vaziable speed drives and manu� <br /> panel. Exhaust shafts to have one fan per shafr mounted at up <br /> gazage. <br /> I • Exhaust fans to be spring mounted and installed with sound tr <br /> • Exhaust to be vertically ducted to roof. . <br /> • Make up air to be fully ducted. <br /> • Exhaust system controlled by cazbon monmcide detection syst <br /> coverage of 1/ 5,000 SF. Detection system to ramp exhaust f <br /> from 50 PPM (0 speed) to 200 PPM (100%). CO panels to h2 <br /> audible and visual alarms. <br /> • Provide A/C systems for Attendant Office and elevator machi <br /> rooms. <br /> • Provide elevator ositive oressure at Elevator Lobbies. <br />