Agmt97 Metcalf & Eddy
RedwoodCity
>
City Clerk
>
Agreements
>
1990-1999
>
1997
>
Agmt97 Metcalf & Eddy
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/5/2005 2:56:58 PM
Creation date
10/2/2003 2:47:06 PM
Metadata
Fields
Template:
Agreement
Contractor Name
Metcalf & Eddy
PROJECT NAME
Redwood Shores sewer pump station #2
RMP File Number
304
Date
1/27/1997
Reso Ref
12981
Box
5862
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Metca -f & Eddu - <br /> An Air & Water Technologies Company <br /> <br /> EXHIBIT "A" <br /> <br />December 13, 1996 <br /> <br />Mr. Jon Lynch <br />City of Redwood City <br />P.O. Box 391 <br />Redwood City, CA 94064 <br />FAX: (415) 780-7309 <br /> <br />Subject: Proposal to Provide Engineering Services for the Design of the <br /> Rehabilitation of Sewage Pump Station No. 2 <br /> <br />Dear Jon: <br /> <br />Metcalf & Eddy, Inc. (M&E) is pleased to provide this proposal for the rehabilitation design <br />of Sewage Pump Station No. 2 in Redwood Shores. This pump station which was <br />constructed in 1968, has experienced deterioration and is now running on temporary pumps. <br />The pump station is in urgent need of repairs. The current effort requires replacement of the <br />pumps, coating of the wet well, abandonment of the existing dry pit, modifications of the <br />structure to provide a new valve vault, installation of a standby generator, replacement of the <br />existing electrical system with a new 480 volt system, and replacement of the control system. <br />The pumps will be sized based on a review of recent flow records and the size of the <br />originally installed pumps. <br /> <br />The following tasks will be performed: <br /> <br />Task 1. Fifty Percent Design <br /> <br />This task will develop the design documents up to approximately the 50 percent complete <br />level. Field verification of relevant dimensions of items not shown on recent topography will <br />be conducted. At this time, additional surveying services are not planned or budgeted. The <br />plans will include layout of equipment and major components. An outline specification will <br />be prepared along with unedited versions of major equipment items. M&E's standard <br />technical specifications in CSI format will be used for pump station components. The City's <br />contract and "boilerplate' will be used for all other provisions. <br /> <br /> Page 1 of 4 <br /> <br />P:\ PROJECTS\RC-PS\PRO FOSAL\REDWOO D2. WPD <br /> <br /> 1804 Embarcadero Road, Suite 100, Palo Alto, CA 94303-3308 <br /> TEL: 415-494-9300 FAX: 415 494-2434 <br /> <br /> <br />