Laserfiche WebLink
i <br /> I <br /> " 6.1. E. - Page 11 �� <br /> � ! <br /> � <br /> ' � <br /> � <br /> � <br /> ; ,S`ection 1- Gene�all�equi�ements , <br /> ; Purpose <br /> I <br /> Contxactor shall develop, design, amd constxuct a vessel based on these specifications for and I <br /> one (1) 36 foot fire vessel for Watersid� MDA -- IED/CBRNE PPR&R Enhancements for the � <br /> Redwood Czty Fixe Department. The vessel is intended to provide firef ghting, xescue, and <br /> � emergency service operations capabilities. The vessel is to meet or exceed �he following <br /> ', Standards: NFPA 1925 for pumping, OSHA Db rating, USCG CFR 46, USCG interior flame <br /> retardant rating, Amexzcan Boating and Yachting Council and �he Amexican Bureau of '. <br /> i Shzpping Welding Staz�.daxds. ; <br /> 1.0 Scone of Worli: <br /> � �.01 The intent af these specifications is to acquiire a vessel (�reboat) to provide fire fighting <br /> and ernergency medical service delivery. f1 crew of four fire fighters will operate the I <br /> fireboat at any given t�me. It is required that speed be achieved at 90% of �e engi�e's rated <br /> hoxsepower, as descxibed in Section 3, Specificatio�s. <br /> � 1.02 Aluminum construction is specified to minimize fireboat weight and reduce hull i <br /> maintenance raquirements. A twin engine, niarine diesel propulsion systein with reverse gear ! <br /> and watex jets is recommei�ded. k'ixe puznps providing up to 4000 GPM capacity at 150 psi �I <br /> axe requested. The fire pumps will dischaxge io � moni�ors (at least one remotely controlled), <br /> 2"�3" outlets and one 5" stortz outlet1.03 The fireboat is required to have a heated and air- ' <br /> ' conditioned cabin/pilothouse to contain the steering station and a bench seai that wi11 also <br /> � ,serve as a Berth for an injured person. Stowage space shall be pravided for firefighting <br /> � equiprnent, emergency medical equi�ament, insulated water jug, a marina sanitation de�ice : <br /> � <br /> with holding tanlc and pump-ou� connections, and other equipmant defined in these <br /> i specifications. <br /> ' 1.43.1 Contrac�;or shall furnish and install all elec�ronics as s�pecified in Secl;ion 3. The �E <br /> I con�raci:or is required to provide po�ver, electrical pa�els, and circuit brcakcrs for these , <br /> systems. � <br /> 1.03.2 The rnanufcrcture� ta whom this bid is aWarded must construct the, fi�eboat desc�ibed � <br /> in this specification in its entirety. Thir�d per�ty, o� sul�-contracting, of fabrication is i <br /> unacc�ptable. I3ids failing to meet this requi�ement t-vill be conside�ed non�espansive and � <br /> will he t�ejected. i <br /> � 1.03.3 These specifications shall be interpreted as the minimum acceptable. While a ' <br /> � s�eciL'ication, in som� cases, describes a speci�c manu�acttrrer or model numk�er which has ; <br /> been determined as acceptable and suited to the Rec�wood Cify Fire Depart�nent's needs, it is � <br /> not intended to eliminate frain consideration any comparable equipment of aqual ' <br /> perPorinance, quality, and value that a manutacturer may havc available, Bids must be � <br /> prepared considering these specifications. Upan project award to the successfiil respondent, <br /> RCPD may determine "Approved �qu�ls" or "Approved Alternatives" during the � <br /> Submittal/Appxoval Process as specified in Section 2. <br /> ' 1.1 rns�ection: <br /> 1.1.1 All ite�ns delivered under this project shall be subject ta inspection by the Redwood <br /> City k'ixe Departfnent. Acceptance thereof v,�ll be coz�tzngent upon the materials passing such , <br /> inspection. Th� R�dwood City Fir� Department will utilize the services of a c�rtified marine <br /> surveyor to inspect/ensure structural, machinery, and safety com�liance wi1;h ABS standards <br /> 2 <br /> ATTY/AGR/2012.076/METALCRAFT MARINE ' <br /> . REV:06-13-12 VR ; <br />