My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
AgdaPkt 2012-06-18 Special
RedwoodCity
>
City Clerk
>
Agenda Packets
>
2010-2019
>
2012
>
AgdaPkt 2012-06-18 Special
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/21/2012 3:39:05 PM
Creation date
6/19/2012 1:35:33 PM
Metadata
Fields
Template:
CC Index
CC Index - Document Type
Agenda Packet
Meeting Type
Special
Agency Type
City Council
Date
6/18/2012
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
154
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
; <br /> I <br /> 6.1. E. - Page 17 i <br /> 3.1.$ There sha11 be three (3) multi,speed wipers that are self parking. j <br /> 3.19 The cabin/pilothouse shall have a weather tigh� door in the aft cabin/pilothouse I <br /> br.rlkhead. Clear opening shall be no less than 30 inches. The door shall have a wii�dow 1/3 � <br /> the length of the doar with 15% tint. The door shall have a 4-inch coaming. The door shall be i <br /> fitt�d with marine quality lockset. The daor shall be insulated and be fully dogged. j <br /> 3.1.10 There shall ba a 24"X24" watertight deck hatch provided for access of fhe void space ' <br /> below th.e z�ain cabin. This space shall be lit and have a tread plaf� d�ck for crew to inspect <br /> the fuel tanlcs as well as use the space for starage of certain fire and EMS gear, j <br /> 3.1.11 Th� floor shall have rubber sound matting installed, ! <br /> 31.12 There shall be tihree (3) suspension crew seats. A fully adjustable helm�man's s�at, ` <br /> with arrnrests sha11 be installed a� th� steering station in accordance with ABYC Helm ' <br /> Position Visibility Standards, j <br /> 3.1.13 A cha� table with lighting and one AC and one DC accessory power outlets. � <br /> 3.L14 There shall be provisions for storing 2{D) CyIinder oxygen tanks. ' <br /> 3.1.15 A bench seat with seat belts for two (2) that can be used a� a patient treatment area. � <br /> There shall be storage available under the bench with divided sliding doars. The � <br /> compartment will be v�nted to cabin air. � <br /> � 311G There sha11 be provisions for four {4) Scott SCBA provided by the Redwood City Fire <br /> Departm�nt. Zico mounting bracket is ta be provided by manufacturer. �,, <br /> 3.117 Zt is reqtiured that a11 interior edges and surfacas be smooth and fair. The interiar sha11 ' <br /> ' be fully fnished. � <br /> � ! <br /> 3.1.1$ All piping shall be conc�aled. <br /> 3.1.1.9 There shall be access to a11 piping, �alves, filters and strainers, 'r <br /> 3.1.20 Grab rails ,shall be ix�s�alled iz� tl�e cabin/pi�otlaouse ovexl�ead a�d run the full length o�' j <br /> � the cabin/pilothouse. <br /> 3.1.21 All attachments af equipment, hardware, fittings, rubber fender and gxab rails shall be <br /> j thxough bolted with stainless steel balts, backing plates, washers and locicnuts. Attachz�ent <br /> using tapped screws ax rivets is pxohibi�ed tiu�less express�y appxoved by The Redwood City , <br /> Fire D�partm�nt, �111 connections shall be insulated to prevent electrolytic corrosion. <br /> i 3.2 Cabin/Pilothonse Exterior: ' <br /> i 3.2.� The roo�' is �o be water tight and self draining. <br /> � � <br /> I ' � <br /> 3.2.2 A marine aluminurn mast shall be pro�vidad to mount inland rui�s navigatian and , <br /> restrzcted iz� ability to maneuver iights, and an emergency beacon light. Mast sk�all have a � <br /> yardarm, The mast shall f�e hinged at or be�ow the fi�ed height o�F the boat struct�are <br /> (including the radar antenna}. Lowering of the mast shall be accomplished from the deck. � <br /> 3.2.3 `The ma,st shall be provided witk� pulleys fox two (2) flag l�aists. Cleats shall be , <br /> provided on the mast for each of the hoists. ' <br /> 3.2.�4 There shall be a two tier radar arch mounted and two watei electrical boxes that are : <br /> - integral to the cabin rooF. The arch shall have enough depth for antennae seating for radar �- <br /> and Forward Looking Tnfra Red (�'LIR) as well as enough space for ap�ropriate antennae I <br /> � spacing per manufacturer's recommendations. There shall be space for two (2) additional <br /> antennas, ; <br /> 3.3 Li�htin� Packa�e: � <br /> 3.3.1 Navigation lights for inland rules shall be installed in accordance vvith U.S. Federal � <br /> regulations and c�ntrolled by labeled switch�s at the steering station contral panel, all lights i <br /> will be oFL�D ty�e, with one green and ane red Iiella LED witli stainIess s1;ee1 bezels. � <br /> A1t�rnativ�s proposals are also accepted, � <br /> i <br /> 8 i <br /> : ATTY/AGR/2012.076/METALCRAFT MARINE <br /> REV:06-13-12 VR � <br /> , I <br />
The URL can be used to link to this page
Your browser does not support the video tag.