My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
Agmt96 Subsurface Consultants
RedwoodCity
>
City Clerk
>
Agreements
>
1990-1999
>
1996
>
Agmt96 Subsurface Consultants
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/5/2005 2:34:45 PM
Creation date
1/29/2004 4:19:24 PM
Metadata
Fields
Template:
Agreement
Contractor Name
Subsurface Consultants
PROJECT NAME
Mezes Plaza project
RMP File Number
405 bin 7A
Date
7/24/1996
Reso Ref
RD96-13
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
EXHIBIT "A" <br /> <br /> PHASE II ENVIRONMENTAL ASSESSMENT <br /> <br /> SCI proposes to perfo~'m a preliminary environmental site assessment to evaluate whettmr <br /> hazardous materials are 1) prescnt in building construcuon materials, 2) ur, ecl/stored on~site or 3) <br /> present in soil and groundwater beneath thc subject parcels. In general, thc assessment will <br /> include tho £oilowing tasks. <br /> <br /> Task i - Site Reconnaissance <br /> <br /> SCI will conduct a reconnaissance of the parcels (inclusive of the entire Mezes Plaza Area~ to <br /> v/anally check for: <br /> <br /> 1. Underground t~-ks, wells or other conditions which ma), represent environmental' <br /> risks. <br /> <br /> 2. Storage or use of hazardous materials, and <br /> <br /> 3. Indications of surface contamination. <br /> <br />,: Task 2 - Agency Records Review <br /> <br /> SCI will review building, f~ and environmental health department files for the project Iots. The <br /> files will be checked for documented environmental concerns. In ~dition, SCI will review <br /> enviror~mental case files for adjacent parcels, <br /> <br /> Task 3 - Building Materials Survey <br /> <br /> SCI will re,in a Certified Industrial Hygienist (CIZI) to ~ thc p~'esence of haz~dou~ <br /> material~ in ex/sting building consuuct/on r~ateri~Is. Representative ~amples of building <br /> materials 'will b~ obtained, by the CIH and analyzed for lead and asbestos, A visual impection <br /> w,211 also be performed by the CIH ~o determine whether PCB containing materials may also be <br /> present. <br /> <br /> Task 4 - Field Investigation <br /> <br /> SCI will drill test borings to approximately 15 feet below the ground surface (bgs) in areas <br /> outsid~ of the existing structure. Prier to drilling, Und .erground Service Alert (USA) will be <br /> contacted to notify utility companies with nearby uncierground facilRies of our totem to drill, so that <br /> utility locations can ~e checked. <br /> <br /> 1 of 3 pages <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.