My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
Ord 2403
RedwoodCity
>
City Clerk
>
Ordinances
>
2010-2019
>
2014
>
Ord 2403
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/16/2014 3:07:26 PM
Creation date
1/16/2014 3:07:26 PM
Metadata
Fields
Template:
CC Index
CC Index - Document Type
Ordinance
Meeting Type
Regular
Agency Type
City Council
Date
1/13/2014
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
01/13/2014 <br /> J103.3. Grading Fees. At the time of filing for a grading permit, the applicant shall <br /> deposit funds to cover the costs of plan checking. Prior to plan approval, <br /> additional fees shall be deposited to cover the costs of inspection. The plan <br /> checking and inspection deposit amounts and City costs shall be established by <br /> resolution of the City Council. Separate plan review and permit fees shall apply to <br /> retaining walls or major drainage structures as required elsewhere in this code. <br /> Sec. 9.61. APPENDIX J OF THE BUILDING CODE AMENDED: Appendix J of the <br /> Building Code is hereby amended to replace the words `Building Official' with the words <br /> `City Engineer' at all locations in this appendix chapter where the words `Building <br /> Official' are found. <br /> Secs. 9.62 - 9.65 RESERVED. <br /> SECTION 4. Article VI of Chapter 9 of the Redwood City Code is hereby added <br /> to read as follows: <br /> CHAPTER 9 ARTICLE VI REDWOOD CITY AMENDMENTS TO 2013 CALIFORNIA <br /> PLUMBING CODE <br /> Sec 9.66. SECTION 604.14 OF THE PLUMBING CODE ADDED: Section 604.14 of <br /> the Plumbing Code is hereby added as follows: <br /> Section 604.14. Metallic water piping shall not be used underground in those <br /> areas underlain by Younger Bay Mud (see map published by Redwood City <br /> Building Division for approximate locations). <br /> Sec. 9.67. SECTION 701.1.7 OF THE PLUMBING CODE ADDED: Section 701.1(7) <br /> of the Plumbing Code is hereby added as follows: <br /> Section 701.1(7). Metallic drainage piping shall not be used underground in <br /> those areas underlain by Younger Bay Mud (see map published by Redwood <br /> City Building Division for approximate locations). <br /> Sec. 9.68. SECTION 715.1 OF THE PLUMBING CODE AMENDED: Section 715.1 of <br /> the Plumbing Code is hereby amended to read as follows: <br /> Section 715.1. The building sewer, beginning two (2) feet (.610mm) from any <br /> building or structure, shall be of such materials as prescribed in this Code. <br /> Nofinrithstanding anything to the contrary, metallic sewer piping shall not be used <br /> underground in those areas underlain by Younger Bay Mud (see map published <br /> by Redwood City Building Division for approximate locations). <br /> Sec. 9.69. SECTION 903.1.4 OF THE PLUMBING CODE ADDED: Section 903.1.4 is <br /> hereby added to the Plumbing Code as follows: <br /> ATTY/ORD398/BUILDING CODE ADOPTION ORD.#2403 <br /> REV:11-22-13 JS FORMERLY MUFF#305 <br /> Page 7 of 9 <br />
The URL can be used to link to this page
Your browser does not support the video tag.