Laserfiche WebLink
g. Renew all wire ropes as often as is necessary to maintain an adequate factor of <br /> safety, equalize the tension on all hoisting ropes, repair or replace conductor <br /> cables and hoist ways and machine room elevator wiring, per ANSI A1 7.2 <br /> Inspectors Manual for elevators and escalators; and <br /> h. Furnish lubricants specifically applicable to the equipment; and. <br /> i. Reshackle cables for drum machines, as required by CAC Title 8; and <br /> j. Shorten and reshackle hoist or compensating cables if stretching of ropes makes <br /> this necessary; and <br /> k. The Contractor shall check the condition and operation of safety edges on car <br /> doors and of light rays on car at every visit, and if light rays are inoperative, shall <br /> repair or renew them within 24 hours. If safety edges are damaged they shall be <br /> repaired or renewed; and. <br /> 1. All lamps in hoist ways, machine rooms, and elevator pits. This includes the <br /> lamps in the glass hoist ways at Lot SIL. <br /> 7. At least quarterly the contractor shall inspect and repair all lamps and bells for car and <br /> hall buttons and arrows as well as the lamps for the location directories above the <br /> elevator doors. This shall be done at all locations and a written report shall be given to the <br /> Maintenance Manager upon completion of the inspection and repair. <br /> 8. Contractor is responsible for controller programming or reprogramming if controller <br /> program is lost or is malfunctioning for any reason. <br /> 9. Contractor is responsible for any and all repairs required and called out in State <br /> inspections. If the contractor does not make the repairs by the deadlines given by the <br /> State,the contractor shall pay for any late fees issued by the State. <br /> 10. Contractor shall not be required to: <br /> a. Refinish, repair, and/or replace elevator car enclosures, hoist way enclosures� <br /> hoist way door panels, frames and sills, and lamps inside the cars, unless the <br /> foregoing are damaged by negligence or misuse by any person or persons <br /> employed by or representing the Contractor. <br /> b. Repair or replace parts damaged by vandalism or negligence. <br /> c. Repair or replace hydraulic cylinders and associated unexposed piping. <br /> d. Repair or replace mainline and auxiliary disconnect switches, fuses, and feeders <br /> to control panels. <br /> ATTY/AGR/2015.043/KONE ELEVATOR RFP GENERAL SERVICES AGR <br /> REV:03-04-15 MLG <br /> Page 8 of 13 <br />