switch, etc.) Motor Control Center cabinet should be sized as required to fit all <br /> components. <br /> 12.Remove and replace existing VFD. Install new Allen Bradley RFX 400 or <br /> Cutler Hammer Model SV 9000 new variable frequency drive (VFD) for each <br /> pump including all components and appurtenances to support Flygt <br /> submersible pumps as required. The said models of VFD are being used by <br /> the City in its other existing pump stations. <br /> 13.Update sanitary sewer programmable logic controller (PLC} unit with Allen <br /> Bradley Micro Logix 1400 or approved equal. <br /> 14.Verify existing electrical connections and electrical bad capacity to conform <br /> to the installation of new sanitary sewer pump station's motor control center, <br /> PLC unit and new Flygt submersible pumps. <br /> 15.Coordinate with utility companies to obtain record information that maybe <br /> affected by the design or construction of the sanitary sewer pump station. <br /> 16.Coordinate with EDCCO for SCADA control system programming work. Contact <br /> Eric Daniel at 650-63-SCADA. <br /> 17.Connect to existing force mains. Point of connection to be field verified. <br /> 18.Conduct start-up and testing of inechanical and electrical structures and <br /> equipment. <br /> 19.Remove and replace existing AC pavement. <br /> 20.Remove and replace existing concrete pad, concrete pavement, concrete <br /> sidewalk and curb and gutter. <br /> 21.Furnish and install 2 inch recycled water pipeline, quick coupler valve, backflow <br /> preventer and other appurtenances. <br /> 22.�andscape restoration including but not limited to grass lawn, plants and <br /> etc. <br /> 23.Perform field investigation of the existing pump station facility to verify <br /> existing conditions. <br /> The above products specified are to replace existing equipment or products. <br /> Recommendations from consultant is requested and will be reviewed by City. <br /> Pump Station#16 (located on Shannon Wav, East of Davit Lane) <br /> 1. Rehabilitate existing wet well surface with new suitable epoxy coating material. <br /> 2. Remove and replace existing submersible pumps with new 5 HP Flygt model <br /> NP 3102 MT, 152 mm impeller diameter, 4" inlet and outlet submersible pumps <br /> or approved equal including pipe assembly and accessories. <br /> 3. Remove and replace the existing pump shoes inside the wet well bottom. It's <br /> the piece that connects to the bottom of the wet well that connects to the <br /> discharge elbow. <br /> 4. Remove and replace existing wet well piping and hardware inside the wet well. <br /> 5. Remove and replace existing valve vautts with precast reinforced concrete box <br /> structures for utility service complete with openings, inserts, floor drain and <br /> hardware. <br /> 6. Remove and replace existing wet well hatch and grate with new Flygt SafeHatch <br /> Model "FLE" with safety grate. <br /> REV:01-04-16 VR <br /> Page 11 of 18 <br /> ATTY/AGR.2016.001NVilsey Ham-Engineering, Surveying&Planning <br />