ATTY/RESO.0043/PC RESO 603 JEFFERSON <br />REV: 05-18-16 VR <br />Page 12 of 19 <br /> <br />Fire and Safety <br />50. Police Radios – Antennas or repeaters shall be installed as necessary throughout the <br />building, including all underground parking levels, to ensure there are no “dead zones” <br />with regard to police hand-held radios. [COA][POLICE] <br />51. Sequential Floor Numbering – All building floors and residential units shall be <br />sequentially numbered (e.g. First Floor units 100, 101, 102, etc.; Second Floor units <br />200, 201, 202, etc.). [COA][POLICE] <br />52. Building Floor Maps – A floor map of the building and units shall be posted at the <br />building entrances as directed by Police and Fire. [COA][POLICE] <br />53. Building Entry Keypads - Keypads allowing 24-hour access for public safety <br />emergency access shall be installed at the residential and garage entrances. <br />[COA][POLICE] <br />54. Key Boxes – Key boxes of sufficient size shall be installed at all entrances to the <br />building. These key boxes shall contain sufficient numbers of keys to allow access to <br />all parts of the building as well as the fire protection equipment and systems. Literature <br />from the manufacturer of these products and ordering information can be obtained <br />from the Fire Department by calling (650) 780-7400 or at www.knoxbox.com. <br />[COA]{FIRE] <br />55. High-Rise Construction – The building meets the definition of a High-Rise and <br />Section 403 of the California Building Code is applicable. [SDR][FIRE] <br />56. Electronic Security Gates – Electronic security gates shall be provided with key <br />switches to provide fire department access.[COA][FIRE] <br />57. Fire Alarm System – A manual fire alarm system shall be installed in Group R-2 <br />occupancies. Manual fire alarm boxes are not required throughout the building when <br />the building is equipped throughout with an automatic fire sprinkler system and <br />notification appliances activate upon sprinkler flow. At least one manual station shall <br />be installed at an approved location. All initiating and indicating devices shall be <br />electronically supervised. For the purposes of fire alarm annunciation, each floor of <br />the building shall be considered a separate zone. Fire alarm signals shall be <br />transmitted to the central station and retransmitted by zone to the public safety <br />communications center.[COA][FIRE] <br />58. Fire Sprinklers – An approved automatic fire sprinkler system with manual wet <br />standpipes shall be installed meeting the requirements of NFPA Standard 13. <br />Location for fire department connections shall be on the Jefferson Street side of the <br />building. In conjunction with the fire sprinkler system, a Class 1 Fire Department <br />Standpipe System (manual wet) shall be provided within each stairwell. <br />All valves controlling the water supply for automatic fire sprinkler systems, pumps, and <br />water flow switches on all fire sprinkler systems shall be electronically supervised. This <br />includes the detector check valves and back-flow prevention devices.