My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
Agmt04 Kennedy Jenks
RedwoodCity
>
City Clerk
>
Agreements
>
2000-2009
>
2004
>
Agmt04 Kennedy Jenks
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/24/2017 10:36:18 AM
Creation date
9/7/2004 8:42:33 AM
Metadata
Fields
Template:
Agreement
Contractor Name
Kennedy Jenks Consultants
PROJECT NAME
recycled water
RMP File Number
304 (was an 802)
Date
9/3/2004
MO Ref
04-163 05-165
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
95
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
<br />service configuration, review requirements of the California Department of Health <br />Services, and ability and/or willingness of the customer to coordinate with the City and <br />consultant team, etc. <br /> <br />. To closely manage the work and provide accurate reporting, each customer retrofit site <br />or group of retrofits will be treated as an individual project. Labor effort, direct costs and <br />construction related budgets and actual costs will be accounted for on a site-by-site <br />basis as part of the Project Management Task. <br /> <br />. The work under this contract is assumed to be performed over a 42 month period, as <br />the treatment, storage, pumping and distribution facilities are constructed and placed <br />into service. If the work under this contract extends beyond this time period, the scope <br />of services and fee will require amendment. <br /> <br />. The assessment of site conditions for hazardous materials is not included. If hazardous <br />materials are encountered during design or construction, addressing these and related <br />issues will constitute a change in scope. <br /> <br />Service Provided by the City <br /> <br />. The City will provide an individual that will serve as a point of contact between the City <br />and the customer. This individual will assist the customer retrofit team in scheduling site <br />work and construction activities, and in procuring agreements for service and site <br />access. <br /> <br />. The City, using its own forces, will design and implement changes to the potable water <br />service pressure in Redwood Shores. The pressure will be increased to approximately <br />85 psi, to create a 10 psi differential above the proposed recycled water service <br />pressure of approximately 75 psi. This will create potential problems with the services to <br />existing commercial buildings and existing irrigation systems that could require the <br />installation of individual pressure reducing assemblies on services or other remedial <br />work. The City will coordinate this work with the implementation of the recycled water <br />project. <br /> <br />. The City will be performing a high level of landscape water conservation effort (BMP 5) <br />simultaneously with the customer retrofit process and will coordinate these efforts with <br />the work under this scope of services. The City will work with customers using in-house <br />and other consultant forces to assure their on-site potable irrigation systems are working <br />properly at the envisioned water pressure of the recycled water system, and prevent <br />overspray and runoff to the extent possible. This work will be performed in advance or <br />concurrent with the retrofit process. Information gathered from customers will be <br />provided for consultants' use. <br /> <br />. The City has contracted separately for program management services that include the <br />development of an Engineering Report, an Operations Plan, and a Customer Training <br />Manual, and overall coordination of regulatory permits with the Regional Water Quality <br />Control Board (RWQCB) and Department of Health Services (DHS). This information <br />will be used in performing work under this scope of services with respect to performing <br />customer training and coordinating DHS approvals of each site retrofit design and <br />conversion. <br /> <br />Agreement over $10K <br />KennedyJenks Rev-2 112603 <br /> <br />3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.