111(3) Ordinance No. 1130 (Zoning). <br />"'(b) The ordinance or Code provisions of this section <br />shall not be construed to preclude the issuance ofa <br />building permit when there are previously or concur- <br />rently issued permits for improvements which would <br />eliminate any noncompliance with the abovementioned <br />ordinances. All such necessary improvements shall <br />be constructed concurrently with the work being done <br />on the structure for which the building permit is issued."' <br />"Section 9.44 Section 309 is hereby added to the Building <br />Code to read as follows: <br />"'Section 309 (a) No building permit or certificate <br />of occupancy shall be issued by the Building Official <br />if the structure to be constructed or the portion to <br />be remodeled lies within or fails to have the necessary <br />setback distance from any area reserved for the <br />construction, widening or extension of the city street <br />system pursuant to action taken by the Council of the City. <br />"'(b) No building permit or certificate of occupancy <br />shall be issued by the Building Official if the <br />structure to'be constructed or the portion to be <br />remodeled lies within any recorded property interest <br />held for public purposes or public utility purposes."' <br />"Section 9.45 Section 2623.1 is hereby added to the Building <br />Code to read as follows: <br />"'Section 2623.1 Concrete Floors: This section shall <br />apply to habitable rooms of Group R-1 and R-3 <br />occupancies only. <br />"'(1) Concrete slab floors shall have a minimum <br />thickness of three and one-half inches <br />O -Y") and shall be reinforced with six <br />inch by six inch by ten (61IX6"X10 ga.) gauge <br />wire mesh. - <br />"(2) A waterproof moisture barrier approved by <br />the Building Official shall be installed <br />directly between the concrete slab floor <br />and granular fill below and must extend <br />to the outer edge of the foundation at its <br />base. When the foundation and floor slab <br />are not poured monolithically such moisture <br />barrier may extend not more than two inches <br />(2") into the joint between the foundation <br />and floor slab. <br />111(3) A granular fill of suitable consistency and <br />thickness shall be provided directly under <br />the concrete slab membrane to retard capillary <br />action and shall be approved by the Building <br />official. <br />"'(4) On level lots the elevation of the concrete <br />floor slab shall be six inches (6") above <br />finished grade. On unimproved lots or <br />sloping ground a six inches (6") elevation <br />must be maintained -above finished grade."' <br />-7- <br />