<br />" (c) <br />and <br />the <br />the <br /> <br />"later piping installed within a building <br />in or under a concrete floor slab resting on <br />ground shall be installed in accordance with <br />following requirements: <br /> <br />"(1) Ferrous piping shall have a protective coating <br />of an approved type, machine applied and co~forming <br />to recognized standards. Field wrapping shall <br />provide equivalent protection and is restricted <br />to those short sections and fittings necessarily <br />stripped for threading. Zinc coating (galvanizing) <br />shall not be deemed adequate protection for piping <br />or fittings. Approved non-ferrous piping need <br />not be wrapped. <br /> <br />"(2) Copper tubing shall be installed without <br />joints where possible. Where joints are permitted, <br />they shall be soldered with 95.5 solder using <br />fittings of wrought copper. <br /> <br />"(d) Inspection. No water supply system or <br />portion thereof, shall be covered or concealed <br />'until it first has been tested, inspected and <br />approved. <br /> <br />"(e) Testing. Before such approval, both hot <br />and cold water piping shall be subjected to a <br />full working water pressure test from the street <br />main or other source of supply, or to an air <br />pressure of not less than 50 pounds per square <br />inch for not less than 15 minutes. Piping must <br />not leak when subjected to such test. <br /> <br />"section 9.99 <br /> <br />Section 1107.1 is hereby added to the <br /> <br />Plumbing Code to read as follows: <br /> <br />"Section 1107.1 t'lhen a main sewer is located in <br />the street, alley or easement, there must be <br />provided a cleanout brought up flush with sidewalk <br />level at the property line. Riser shall be of <br />cast iron or other approved material, the same <br />size as the drain it serves, brought up to the <br />level of the ground or sidewalk by a wye and <br />branch fittings, and top of same to be provided <br />with a regulation cleanout. If the sidewalk space <br />mentioned is adjacent to buildings at the property <br />line then a cast iron side\';alk box, with loose <br />cover fitted with brass screws, shall be installed <br />a minimum of two feet from the property line. <br />The size for a cleanout plug shall be four inches. <br /> <br />"section 9.100 <br /> <br />Section 1310.1 is hereby added to the <br /> <br />Plumbing Code to read as follows: <br /> <br />"Section 1310.1 water heaters shall have safety <br />pans with drains when located in living area or <br />when leakage would do damage to the building or <br /> <br />-27.- <br />