My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
Res13 15294
RedwoodCity
>
City Clerk
>
Resolutions
>
City Council
>
Working
>
2010-2019
>
Res13 15294
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/11/2019 7:50:36 AM
Creation date
10/11/2019 7:50:22 AM
Metadata
Fields
Template:
CC Index
CC Index - Document Type
Resolution
Meeting Type
Regular
Agency Type
City Council
Date
9/9/2013
Description
A RESOLUTION OF THE CITY COUNCIL OF THE CITY OF REDWOOD CITY CERTIFYING THE FINAL ENVIRONMENTAL IMPACT REPORT FOR THE STANFORD IN REDWOOD CITY PRECISE PLAN; ADOPTING CEQA FINDINGS; ADOPTING A STATEMENT OF OVERRIDING CONSIDERATIONS FOR EACH SIGNIFICANT UNAVOIDABLE ENVIRONMENTAL IMPACT IDENTIFIED IN THE EIR; AND ADOPTING A MITIGATION MONITORING AND REPORTING PLAN, ALL IN ACCORDANCE WITH THE REQUIREMENTS OF THE CALIFORNIA ENVIRONMENTAL QUALITY ACT
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
91
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
09/09/2013 <br /> Finding: Implementation of Mitigation 13-3 would reduce this potential intermittent and <br /> short-term project vibration impact to a less-than-significant level. <br /> Facts in Support of Finding: Implementation of Mitigation 13-3 would reduce project-facilitated <br /> groundborne demolition and construction vibration levels to a less-than- <br /> significant level by restricting vibration-generating activity and applying <br /> quantitative performance standards. These facts are described and quantified in <br /> Draft EIR chapter 13 (Noise) on pages 13-1 through 13-20, which is hereby <br /> incorporated by reference. <br /> Impact: Impact 13-4: Potential Noise from Parking Structure Ventilation System. <br /> Noise generated solely by the ventilation system and other mechanical <br /> equipment for the potential parking structure at the corner of Bay Road and <br /> Barron Avenue could substantially exceed existing ambient levels at residences <br /> in the area or the Redwood City Noise Guidelines for Land Use Planning (see <br /> Draft EIR Table 13.4) because the parking structure would be located proximate <br /> to residences on 2"d Avenue. <br /> Mitigation: Mitigation 13-4. During the project detailed design phase for the potential <br /> parking structure at the corner of Bay Road and Barron Avenue, the project <br /> applicant shall submit an acoustical study to demonstrate how the parking <br /> structure design would meet the following noise standards at the most affected <br /> receiver: 60 dBA CNEL and 60 dBA Leq-n�daytime (7:00 AM to 7:00 PM), 55 dBA <br /> Leq-hr evening (7:00 PM to 10:00 PM), and 50 dBA LeQ-n� nighttime (10:00 PM to <br /> 7:00 AM). The design measures may include, for example, the installation of <br /> silencers and baffles as necessary to reduce the noise level at the nearest <br /> residential property line to the existing ambient noise level. <br /> Finding: Implementation of Mitigation 13-4 to the satisfaction of the Redwood City <br /> Community Development Department would reduce this ventilation noise impact <br /> to a less-than-significant level. <br /> Facts in Support of Finding: Implementation of Mitigation 13-4 would reduce noise from the <br /> parking structure ventilation system proposed for the corner of Bay Road and <br /> Barron Avenue, which is near residences on 2"d Avenue, to a less-than- <br /> significant level. The mitigation defines maximum allowable decibel levels <br /> (performance standards), which are typically met through standard ventilation <br /> design measures such as silencers and baffles. These facts are described and <br /> quantified in Draft EIR chapter 13 (Noise) on pages 13-1 through 13-20, which is <br /> hereby incorporated by reference. <br /> Transportation, Circulation, and Parkinq <br /> Impact: Impact 7-1: Existing Plus Project Impact on Woodside Road/Broadway <br /> Intersection. Under Existing Plus Project conditions during the PM peak hour, <br /> project traffic would cause the intersection to degrade from LOS E (59.3 seconds <br /> delay) to LOS F (128.8 seconds delay). <br /> ATTY/RES0.2901/STANFORD EIR CERTIFICATION RESO.#15294 <br /> REV:09-10-13 VR MUFF#100 <br /> Page 25 of 55 <br />
The URL can be used to link to this page
Your browser does not support the video tag.