A RESOLUTION OF THE CITY COUNCIL OF THE CITY OF REDWOOD CITY APPROVING AN ARCHITECTURAL PERMIT, PLANNED DEVELOPMENT PERMIT, USE PERMIT, VESTING TENTATIVE MAP, STATE DENSITY BONUS LAW CONCESSIONS AND AN AFFORDABLE HOUSING PLAN FOR THE BROADWAY PLAZA PROJECT LOCATED AT 1401 BROADWAY AND 2201 BAY ROAD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
05/20/2019 <br />64. Fire Alarm Systems Required - UL Central Station fully addressable fire alarm systems are <br />required in all buildings meeting NFPA 72. Provide plans and voltage drop calculations for the <br />design of these systems. [SDR][FIRE] <br />6S. Emergency Escape and Rescue Openings - All sleeping rooms must all be provided with <br />emergency escape and rescue openings in accordance with CBC 1030. Confirm the design of the <br />project includes compliant openings and those openings have ladder access for use by the fire <br />department in an emergency. Show the point of ladder access on the fire department access <br />plans. The proposed construction type of the residential buildings was not indicated on the <br />plans. Due to the elevation changes to the top of the podium, and the difficulty in accessing all <br />of the sleeping room windows with ladders, it is recommended that the construction type for <br />the residential structures be Type IIIA or IIA which would allow for the elimination of the <br />rescue and escape window requirements. [SDR][FIRE] <br />66. Premises Identification (Address Numbers) - Indicate on the plans where the premises <br />identification (address) will be located and the size (minimum 12") in an illuminated and <br />contrasting background facing the street from which the building takes the address. [SDR -CFC <br />505][FIRE] <br />67. Gurney Accommodating Elevator Requirement - Elevators in buildings that are four stories <br />or more shall provide for fire department emergency access to all floors. At least one elevator <br />car in each building shall be of such a size and arrangement to accommodate an ambulance <br />gurney 24 inches by 84 inches with not less than 6 -inch radius corners, in the horizontal, open <br />position and shall be identified by the international symbol for emergency medical service. The <br />symbol shall not be less than 3 inches high and shall be placed inside on both sides of the hoist - <br />way door frame. [SDR -CBC 3 002.4.) [FI RE] <br />68. Portable Fire Extinguishers Required - Portable fire extinguishers, with a minimum <br />classification of 2A: 1013C are required to be permanently installed in all buildings within 75 feet <br />of travel from all portions of the building in compliance with NFPA 10 and CFC 906. [SDR][FIRE] <br />Construction -Related Activities <br />69. Verification for Dimensions-Alldimensions, including building location on the site, setbacks, <br />building height, etc. shall be verified by a licensed surveyor. A survey report shall be provided <br />to the Building Inspector for review and approval. [COA][BUILDING) <br />70. Sales and Use Taxes - Applicant shall use good faith efforts to register with the Board of <br />Equalization to create an ID prior to project construction and operation. This maximizes the <br />City's allocation of sales and use taxes associated with project construction. Contact Nancy <br />Murguia, Finance Department, at (650) 780-7097 or <br />nmurguiaRredwoodcity.org. [COA][FINANCE] <br />71. Hours of Construction - On -Site Construction activity is permitted between 7:00 a.m. and 8:00 <br />p.m. Monday through Friday, except as permitted on weekends by the Building Official, and <br />shall adhere to the City's Noise Ordinance. If possible, the noisiest construction activities would <br />be scheduled for daytime hours when the ambient noise levels are highest. [SDR] [BUILDING] <br />72. Construction Sign - Prior to the start of any construction work, including demolition, install at <br />least one 36" x 48" (minimum) construction sign in a visible location along the project frontage <br />ATTY/RESO.0051 CC RESO APPROVING PROJECT — BROADWAY PLAZA RE50. NO. 15769 <br />REV: 05-15-19 PR MUFF NO. 601 <br />Page 19 of 22 <br />