8.113. - Page 43 of 63 <br />Sec. 9.237. - SECTION 4.106.4.2.1.1 OF THE GREEN BUILDING STANDARDS CODE <br />AMENDED: <br />Section 4.106.4.2.1.1 of the Green Building Standards Code is amended to read as <br />follows: <br />4.106.4.2.1.1 Electric vehicle charging stations (EVCS). When EV chargers are <br />installed, EV spaces required by Section 4.106.4.2.2, Item 3, shall comply with at <br />least one of the following options: <br />A. The EV space shall be located adjacent to an accessible parking space <br />meeting the requirements of the California Building Code, Chapter 11A, to allow <br />use of the EV charger from the accessible parking space. <br />B. The EV space shall be located on an accessible route, as defined in the <br />California Building Code, Chapter 2, to the building. <br />EXCEPTION: Electric vehicle charging stations designed and constructed in <br />compliance with the California Building Code, Chapter 11 B, are not required to <br />comply with Section 4.106.4.2.1.1 and Section 4.106.4.2.2, Item 3. <br />Note: The Division of the State Architect provides guidance on exemptions from <br />Chapter 11 B EV infrastructure accessibility requirements, such as buildings that <br />are not subject to Chapter 11 B and assigned parking spaces at buildings that are <br />subject to Chapter 11 B. <br />Sec. 9.237. - SECTION 4.106.4.2.2 OF THE GREEN BUILDING STANDARDS CODE <br />AMENDED: <br />Section 4.106.4.2.2 of the Green Building Standards Code is amended to read as follows: <br />4.106.4.2.2 Electric vehicle charging space (EV space) dimensions. The EV <br />spaces shall be designed to comply with the following: <br />A. The minimum length of each EV space shall be 18 feet (5486 mm). <br />B. The minimum width of each EV space shall be 9 feet (2743 mm). <br />C. One in every 25 EV spaces, but not less than one, shall also have an 8 -foot <br />(2438 mm) wide minimum aisle. A 5 -foot (1524 mm) wide minimum aisle shall <br />be permitted provided the minimum width of the EV space is 12 feet (3658 mm). <br />Surface slope for this EV space and the aisle shall not exceed 1 unit vertical in <br />48 units <br />Sec. 9.238. - SECTION 4.106.4.2.3 OF THE GREEN BUILDING STANDARDS CODE <br />AMENDED: <br />Section 4.106.4.2.3 of the Green Building Standards Code is amended to read as follows: <br />4.106.4.2.3 Good Design Practices. For all projects subject to California Code of <br />Regulations Title 24, Part 2, Chapter 11 B, construction documents shall indicate <br />how many accessible EVCS would be required as per Title 24, Chapter 11 B to <br />ATTY/ORD.504/CC ORDINANCE ADDING CALIFORNIA ENERGY CODE & GREEN BUILDING STANDARDS <br />REV: 10-24-19 RL <br />Page 15 of 18 <br />187 <br />