My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
AgdaPkt 2021.02.22 Joint SA PFA
RedwoodCity
>
City Clerk
>
Agenda Packets
>
2020-2029
>
2021
>
AgdaPkt 2021.02.22 Joint SA PFA
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2021 4:51:32 PM
Creation date
2/18/2021 5:12:39 PM
Metadata
Fields
Template:
CC Index
CC Index - Document Type
Agenda Packet
Meeting Type
Joint
Agency Type
City Council and Successor Agency and Public Financing Authority
Date
2/22/2021
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
657
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
6.J. - Page 15 of 86 <br />Attachment A <br />■ Project closeout documentation (Warranty documentation, submittals, IOM's and <br />startup paperwork) <br />City shall provide Contractor with the following for AC unit replacement: <br />■ As -built drawings of mechanical, plumbing, electrical, structural and architectural for <br />engineering. <br />■ 120 volt power within 10' of unit <br />Permission to swing crane in two mobilizations with and without load over building <br />■ Free and clear access to work area, restroom, break area and building ingress/egress <br />during all phases of work <br />Scope and Fee are based on: <br />■ Existing condensate drain size, routing and drain location being suitable for reuse <br />without modification <br />• Existing duct mounted smoke detectors being suitable for reuse <br />■ Demolition to occur the day prior to rigging for removal <br />Project #2: Building Automation System <br />Contractor shall provide equipment and services for retrofitting and installation of a new <br />building automation system as delineated below: <br />■ Qty. (1) Tracer SC Building Automation System Controller <br />o Non-proprietary BACnet protocol <br />o Web -enabled interface <br />o Standard 3D Graphics for equipment <br />■ Qty. (20) VAV Box DDC field retrofit kits utilizing UC210 BACnet AirFi (tagged VAV-01 <br />through VAV-20) <br />Each zone to include: <br />o Programmable BACnet DOC controller <br />o (1) Air valve actuator damper motor <br />o (0) Reheat Valve (Reuse Existing) <br />o (1) Pressure transducer <br />o (1) Discharge air temperature sensor <br />o (1) AirFi wireless LED zone sensor <br />Each zone will share: <br />o 120/24VAC Transformer (Supplied by Contractor) <br />• Boiler (TCP MZ2-1) retrofit with BACnet UC600 Controller <br />o Programmable UC600 BACnet DDC controller <br />■ AHU-1 (PEM 1-1) retrofit with BACnet UC600 Controller <br />o Programmable UC600 BACnet DDC controller <br />AHU-2 (PEM 1-2) retrofit with BACnet UC600 Controller <br />REV: 01-22-2021 MI <br />ATTY/AGR.2021.012/Pacific Coast Sales & Service, Inc (Page 12 of 13) <br />433 <br />
The URL can be used to link to this page
Your browser does not support the video tag.