Laserfiche WebLink
<br />ATTY/RESO.0125/PC RESO SOUTH MAIN MIXED USE PROJECT – ENTITLEMENT <br />REV: 10-27-2020 PR <br />Page 33 of 38 <br /> <br />climbing angle for the aerial apparatus ladder to the roof of each building. <br />ii. Any proposed street trees shall be of a species that will not impede aerial <br />apparatus ladder access to the roof of each building. <br />iii. Spacing of street trees shall be factored into this consideration based on the <br />expected height and width of the tree foliage. <br />iv. Mature street tree height and width shall be determined utilizing a <br />scientifically supported methodology such as the Urban Forest Ecosystems <br />Institute at Cal-Poly University https://ufei.calpoly.edu/ <br />65. Street Trees - Any proposed street trees shall be of a species that will not impede aerial apparatus <br />ladder access to the roof of each building. a. Spacing of street trees shall be factored into this consideration based on the expected <br />height and width of the tree foliage. b. Mature street tree height and width shall be determined utilizing a scientifically <br />supported methodology such as the Urban Forest Ecosystems Institute at Cal-Poly <br />University https://ufei.calpoly.edu/ <br />66. Dead-End Fire Apparatus Access Roads in excess of 150 feet in length shall be provided with an <br />approved area for turning around fire apparatus at the end 503.2.5. a. The plans indicate the proposed fire apparatus turn around that includes the garage <br />entrances to Parcel E meets the specifications in Appendix D of the 2019 California <br />Fire Code. <br />67. Requirements Accessible - All of the requirements defined in section 12.23 of the Redwood City <br />Municipal Code shall be incorporated into each of the buildings including equipment cache rooms, <br />public address systems, and emergency planning and information signage. <br />68. Gurney Accommodating Elevators Required - Elevators are required to be provided in all buildings <br />that are four stories or more. Elevators shall be provided for fire department emergency access to <br />all floors. The elevator car shall be of such a size and arrangement to accommodate an ambulance <br />stretcher 24 inches by 84 inches with not less than 6-inch radius corners, in the horizontal, open <br />position and shall be identified by the international symbol for emergency medical service. The <br />symbol shall not be less than 3 inches high and shall be placed inside on both sides of the hoist-way <br />door frame CBC 3002.4. a. The plans indicate that this condition will be addressed. <br />69. Portable Fire Extinguishers Required - Portable fire extinguishers, with a minimum classification of <br />2A:10BC are required to be permanently installed in all buildings within 75 feet of travel from all <br />portions of the building in compliance with NFPA 10 and CFC 906. <br />70. Radio Coverage for Emergency Responders – All building and parking garages shall have approved <br />radio coverage for emergency responders within the building. Upon completion of the building