Laserfiche WebLink
ATTY/RESO.0012/PC RESO GRANTING APPROVAL OF AN ARC PERMIT FOR 240 TWIN DOLPHIN DR <br />REV: 03-11-2021 PR <br />Page 13 of 21 <br />also submit certification by a registered professional engineer or architect that the standards for elevation and floodproofing have been satisfied. [COA][ENGINEERING] Utility Infrastructure Improvements 33. Conformance with the City’s Engineering Standards – All public improvements shall be designed and constructed in accordance with the City’s Engineering Standards. [SDR][ENGINEERING] 34. Encroachment Permits – Obtain an Encroachment Permit from the Engineering and Transportation Division for work listed below. This permit shall be obtained prior to the commencement of construction of the road, utilities, or any site improvements. [SDR][ENGINEERING] a. Work in the City public right-of-way, easements or property in which the City holds an interest. b. Work requiring a grading permit. Grading permits require a Plot and Finished Grading Plan prepared by a California-registered Civil Engineer. c. Work requiring on-site shoring which affects the public right of way d. Work using the public right-of-way for any fixed structure (awnings, roof overhangs, fixed planters, etc.). Insurance, meeting the City’s standards, is required. This permit will be recorded against the property. 35. Sewer Capacity – Prior to encroachment permit issuance, submit to the City, and obtain approval of, an evaluation and report prepared by a licensed engineer demonstrating that the existing sewer mains have sufficient capacity for the project. The study shall consider existing, project, other approved projects, and applications currently under review in determining the needed capacity. If the existing sewer main is less than 6” in size, or is in any other way not sufficient as determined by the City Engineer, applicant shall, as part of the Project, construct and install new sewer mains sufficient to meet such requirements, in accordance with the City's Engineering standards and as directed by the City Engineer to the City Engineer's satisfaction. [SDR][ENGINEERING] 36. Sewer Pump Station Capacity – Prior to encroachment permit issuance, submit to the City, and obtain approval of, an evaluation and report prepared by a licensed engineer demonstrating that the existing downstream sewer pump station and force-main system have sufficient capacity for the project. If capacity is not available within the downstream pump station(s) or force-main(s), the project shall be required to design and install improvements as needed to provide for the additional flows. [SDR][ENGINEERING] 37. Sewer Lateral Limit – The project is limited to one sewer lateral per parcel, unless otherwise approved by the Engineering Division. [COA][ENGINEERING] 38. Sewer Lateral Size for Commercial Development - For new or remodeled commercial buildings, sewer laterals less than 4” shall be upgraded to a minimum 6” size. [SDR] [ENGINEERING] 39. Water Mains – Prior to encroachment permit issuance, submit to City, and obtain approval of, an evaluation and report, prepared by a licensed engineer, in conformance with the City's Engineering Standards, demonstrating that the proposed water main meets the domestic and