My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
Agmt24 Star Elevator, Inc.
RedwoodCity
>
City Clerk
>
Agreements
>
2020-2029
>
2025
>
Under $108K
>
Agmt24 Star Elevator, Inc.
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/19/2025 3:40:35 PM
Creation date
2/19/2025 3:33:23 PM
Metadata
Fields
Template:
Agreement
Contractor Name
levator inspections, preventative maintenance, and repair services.
RMP File Number
304.5
Date
2/16/2024
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
REV: 02-04-25 LF <br />stop motion switches; and <br />ii) Motor and motor generator, motor windings, rotating element, commutator, <br />brushes, brush holders and bearings; and <br />iii) Controller, selector and dispatching equipment, all relays, solid state <br />components, resistors, condensers, transformers, contacts, leads, <br />dashpots, tuning devices, computer devices, steel selector tape and <br />mechanical and electrical driving equipment; and <br />iv) Governor, governor sheave and shaft assembly, bearings, contacts, and <br />governor jaws; and <br />v) Deflector, car and counterweight sheaves, bearings, car and counterweight <br />buffers, car and counterweight guide rails, top and bottom limit switches, <br />governor tension sheave assembly, compensating sheave assembly, <br />counterweight and counterweight guide shoes, including rollers or gibs, and <br />rebabbitt counterweights when necessary; and <br />vi) Hoist way door interlocks, hoist way door hangers, bottom door guides and <br />auxiliary door closing devices; and <br />vii)All lamps in hoist ways, machine rooms, and elevator pits. This includes <br />the lamps in the glass hoist ways at Lot SIL. <br />viii) Renew all wire ropes as often as is necessary to maintain an adequate <br />factor of safety, equalize the tension on all hoisting ropes, repair or replace <br />conductor cables and hoist ways and machine room elevator wiring, per <br />ANSI A1 7.2 Inspectors Manual for elevators and escalators. <br />ix) Furnish lubricants specifically applicable to the equipment. <br />x) Re-shackle cables for drum machines, as required by CAC Title 8. <br />xi) Shorten and re-shackle hoist or compensating cables if stretching of ropes <br />makes this necessary. <br />xii)Check the condition and operation of safety edges on car doors and of light <br />rays on car at every visit, and if light rays are inoperative, shall repair or <br />renew them within one (1) business day. If safety edges are damaged, they <br />shall be repaired or renewed. <br />•At least quarterly the Contractor shall inspect and repair all lamps and bells for <br />car and hall buttons and arrows as well as the lamps for the location directories <br />above the elevator doors. This shall be done at all locations and a written report <br />ATTY/AGR.2025/Amend. no.1/Star Elevator, Inc. (Elevator Maintenance Services) (Page 5 of 11)
The URL can be used to link to this page
Your browser does not support the video tag.