REV: 01-16-24 MI
<br />Assign primary and backup technician(s) to the account. An account
<br />representative shall also be assigned to be the contact for communications
<br />regarding the contract.
<br />Set up specific days that preventative maintenance shall occur each month and
<br />notify City of that schedule. If the service person is called away during the
<br />scheduled maintenance and cannot complete the work, they will return the next
<br />working day.
<br />Repair or replace:
<br />i) Machine drive sheave or drum, drive sheave or drum shaft bearing, brake
<br />pulley, brake coil, brake contact, lungs and component parts, drum buffers, stop
<br />motion switches; and
<br />ii) Motor and motor generator, motor windings, rotating element, commutator,
<br />brushes, brush holders and bearings; and
<br />iii) Controller, selector and dispatching equipment, all relays, solid state
<br />components, resistors, condensers, transformers, contacts, leads, dashpots,
<br />tuning devices, computer devices, steel selector tape and mechanical and
<br />electrical driving equipment; and
<br />iv) Governor, governor sheave and shaft assembly, bearings, contacts, and
<br />governor jaws; and
<br />v) Deflector, car and counterweight sheaves, bearings, car and counterweight
<br />buffers, car and counterweight guide rails, top and bottom limit switches,
<br />governor tension sheave assembly, compensating sheave assembly,
<br />counterweight and counterweight guide shoes, including rollers or gibs, and
<br />rebabbit counterweights when necessary; and
<br />vi) Hoist way door interlocks, hoist way door hangers, bottom door guides and
<br />auxiliary door closing devices; and
<br />vii) All lamps in hoist ways, machine rooms, and elevator pits. This includes the
<br />lamps in the glass hoist ways at Lot SIL.
<br />viii) Renew all wire ropes as often as is necessary to maintain an adequate factor
<br />of safety, equalize the tension on all hoisting ropes, repair or replace conductor
<br />cables and hoist ways and machine room elevator wiring, per ANSI A1 7.2
<br />Inspectors Manual for elevators and escalators.
<br />ix) Furnish lubricants specifically applicable to the equipment.
<br />ATTY/AGR.2024.006/Star Elevator, Inc. (Elevator Maintenance Services) (Page 13 of 19)
|