My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
Reso25 16301
RedwoodCity
>
City Clerk
>
Resolutions
>
City Council
>
2020-2029
>
2025
>
Reso25 16301
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/29/2025 4:12:53 PM
Creation date
4/29/2025 4:10:01 PM
Metadata
Fields
Template:
CC Index
CC Index - Document Type
Resolution
Meeting Type
Regular
Date
4/28/2025
Jump to thumbnail
< previous set
next set >
Text box
ID:
1
Creator:
REDWOOD_CITY\NANCYRAMIREZ
Created:
4/29/2025 4:12 PM
Modified:
4/29/2025 4:12 PM
Text:
https://library.municode.com/ca/redwood_city/codes/city_code?nodeId=CH18LOIMPL_ARTXIVLODEST_S18.243PERE
ID:
2
Creator:
REDWOOD_CITY\NANCYRAMIREZ
Created:
4/29/2025 4:12 PM
Modified:
4/29/2025 4:12 PM
Text:
https://library.municode.com/ca/redwood_city/codes/city_code?nodeId=CH18LOIMPL_ARTXIVLODEST_S18.242UNUT
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
343
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
ATTY/RESO.0034/CC RESO APPROVING PROJECT (901 EL CAMINO REAL) – EXHIBIT A <br />REV: 04-22-25 VR <br />Page 11 of 28 <br />41. Encroachment Permits – The Applicant shall obtain an Encroachment Permit from the <br />Engineering and Transportation Director for work listed below. This permit shall be <br />obtained prior to the commencement of construction of the road, utilities, or any site <br />improvements. [SDR][ENGINEERING] <br /> <br />• Work in the City public right-of-way, easements or property in which the City holds an <br />interest. <br />• Work requiring a grading permit. Grading permits require a Plot and Finished Grading <br />Plan prepared by a California-registered Civil Engineer. <br />• Work requiring on-site shoring which affects the public right of way <br />• Work using the public right-of-way for any fixed structure (awnings, roof overhangs, <br />fixed planters, etc.). Insurance, meeting the City’s standards, is required. This permit <br />will be recorded against the property. <br />• Applicant shall provide proof of insurance, meeting the City’s standards, as determined <br />by the City Engineer, prior to undertaking work under and Encroachment Permit. <br />• This permit will be recorded against the property. <br /> <br />42. Sewer Capacity – Prior to building permit issuance, the Applicant submit to the City, and <br />obtain approval of, an evaluation and report prepared by a licensed engineer <br />demonstrating that the existing sewer mains have sufficient capacity for the Project. The <br />study shall consider existing, project, other approved projects, and applications currently <br />under review in determining the needed capacity. If the existing sewer main is less than 6” <br />in size, or is in any other way not sufficient as determined by the City Engineer, Applicant <br />shall, as part of the Project, construct and install new sewer mains sufficient to meet such <br />requirements, in accordance with the City's Engineering standards and as directed by the <br />City Engineer to the City Engineer's satisfaction. If the City adopts a development impact <br />fee or other funding mechanism related to such infrastructure, the Applicant may pay the <br />applicable fee, if the City Engineer determines that doing so would be equally effective. <br />[SDR][ENGINEERING] <br />43. Sewer Mains – New 12” sewer mains shall be constructed as part of the Project’s <br />realignment of the streets on new Franklin Street and James Avenue. [COA][ENGINEERING] <br />44. Sewer Lateral Limit – The Project is limited to one sewer lateral per parcel. <br />[COA][ENGINEERING] <br />45. Water Mains – Prior to encroachment permit issuance, the Applicant shall submit to City, <br />and obtain approval of, an evaluation and report, prepared by a licensed engineer, in <br />conformance with the City's Engineering Standards, demonstrating that the proposed <br />water main meets the domestic and fire flow requirements in accordance with City Code <br />Section 38.26 and the International Fire Code. If the existing water main is less than 6” in <br />size, or is in any other way not sufficient as determined by the City Engineer, Applicant shall, <br />as part of the Project, construct and install new water mains sufficient to meet such
The URL can be used to link to this page
Your browser does not support the video tag.